ARI CERTIFIED COMBINATION RATINGS

Product Specifications

ARI CERTIFIED COMBINATION RATINGS

 

 

 

 

 

COOLING

 

 

 

HEATING

 

 

UNIT

OUTDOOR

INDOOR

FACTORY

 

 

 

HIGH TEMP

LOW TEMP

 

SUPPLIED

TOTAL

 

 

 

SIZE

MODEL

MODEL

SEER

EER

 

 

 

 

HSPF

ENHANCEMENT

CAPACITY

 

 

 

 

CAPACITY

COP

CAPACITY

COP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CH18ABD1VF

AFPB24A1

TXV, TDR

18,000

13.0

11.0

17,300

3.42

11,100

2.36

8.2

18

 

 

 

 

 

 

 

 

 

 

 

CH18ABD1VF

AFPB24B1

TXV, TDR

18,000

13.0

11.0

17,300

3.42

11,100

2.36

8.2

 

 

 

 

 

 

 

 

 

 

 

 

 

24

CH24ACD1VF

AFPB24B1

TXV, TDR

24,000

13.0

11.4

24,000

3.42

15,000

2.20

8.2

 

 

 

 

 

 

 

 

 

 

 

 

30

CH30ACD1VF

AFPB36A1

TXV, TDR

28,000

13.0

11.5

28,000

3.50

18,200

2.30

8.2

 

 

 

 

 

 

 

 

 

 

 

 

36

CH36ACD1VF

AFPB36A1

TXV, TDR

34,000

13.0

11.5

34,000

3.50

22,000

2.50

8.2

 

 

 

 

 

 

 

 

 

 

 

 

 

CH42ACD1VF

AFPC48A1

TXV, TDR

40,000

13.0

11.5

40,000

3.42

23,000

2.30

8.2

42

 

 

 

 

 

 

 

 

 

 

 

CH42ACD1VF

AFPC48B1

TXV, TDR

40,000

13.0

11.5

40,000

3.42

23,000

2.30

8.2

 

 

 

 

 

 

 

 

 

 

 

 

 

48

CH48ACD1VF

AFPC48B1

TXV, TDR

46,000

13.0

11.5

44,000

3.42

28,400

2.50

7.8

 

 

 

 

 

 

 

 

 

 

 

 

60

CH60ACZ1VF

AZFPC60B1

TXV, TDR

56,000

13.0

11.2

56,000

3.42

38,000

2.30

8.2

 

 

 

 

 

 

 

 

 

 

 

 

SEER – Seasonal Energy Efficiency Ratio

COP – Coefficient of Performance

TDR – Time – Delay Relay

HSPF – Heating Seasonal Performance Factor

EER – Energy Efficiency Ratio

NOTES:

1.Tested combination per ARI 210/240 standard. Fedders air handlers contain the TDR as standard equipment.

2.Supplemental electric heat is not included.

3.Ratings are based on:

Cooling Standard: 80ºF db 67ºF wb indoor entering air temperature and 95ºF db air entering outdoor unit.

High – Temp Heating Standard: 70ºF db indoor entering air temperature and 47ºF db 43ºF wb air entering outdoor unit.

Low – Temp Heating Standard: 70ºF db indoor entering air temperature and 17ºF db 15ºF wb air entering outdoor unit.