Product Specifications
DIMENSIONS (inches)
MODEL | WIDTH | DEPTH | HEIGHT | SUPPLY | |
A | B | C | F x G | ||
| |||||
|
|
|
|
| |
17 1/2 | 28 1/4 | 35 | 16 1/2 X 19 | ||
|
|
|
|
| |
20 1/2 | 28 1/4 | 35 | 19 1/2 X 19 | ||
|
|
|
|
| |
22 | 28 1/4 | 35 | 21 X 19 | ||
|
|
|
|
| |
|
| RETURN |
|
| |
MODEL | SIDE | BOTTOM | VENT | ||
| |||||
| D x E | J x K | L | H | |
|
| ||||
|
|
|
|
| |
14 x 22 | 14 1/2 x 22 | 1 1/2 | 4 | ||
|
|
|
|
| |
14 x 22 | 16 x 22 | 2 1/4 | 4 | ||
|
|
|
|
| |
14 x 222 | 19 x 22 | 1 1/2 | 5 1 | ||
|
|
|
|
|
CLEARANCE TO COMBUSTIBLES (inches)
SURFACE | UPFLOW | DOWNFLOW | HORIZONTAL | ||
Top | 1 | 0 |
| 2 | |
|
|
|
| ||
Front | 3 1/2 | 3 1/2 | 3 1/2 | ||
|
|
|
|
| |
Flue | 6 | 6 |
| 6 | |
|
|
|
|
| |
Flue | 1 | 1 |
| 1 | |
|
|
|
|
| |
Back | 0 | 0 |
| 0 | |
|
|
|
|
| |
Side or End | 0 | 0 |
| 1 | |
|
|
|
|
| |
Floor | 0 | 0 |
| 0 | |
|
|
|
|
|
|
Supply Air Plenum | 1 | 1 | Top |
| End |
|
|
| |||
3 |
| 1 | |||
|
|
|
| ||
|
|
|
|
|
|
Return Air Plenum | 0 | 0 |
| 0 | |
|
|
|
|
|
|
FIELD-INSTALLED ACCESSORIES
PART | DESCRIPTION | MODEL | |
NUMBER | USED WITH | ||
| |||
|
|
| |
30482 | Natural to LP gas conversion kit | All | |
|
|
| |
30551 | LP to Natural gas conversion kit | All | |
|
|
| |
30476 | Combustible Floor | Downflow Only | |
|
|
| |
30553 | High Altitude Kit - US | All | |
|
|
| |
30552 | High Altitude Kit - Canada | All | |
|
|
|
NOTE: Combustible floor kit required for the downflow configuration
1.Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code. Field supplied 5" to 4" reducer kit required for model
2.Two return air openings required.
3
Specifications subject to change without notice.