Product Specifications
PRODUCT SPECIFICATIONS
| Model Number | ||||
|
|
|
|
|
|
| PERFORMANCE RATINGS |
|
|
| |
| Input - High Fire (Btu) - Second Stage1 | 68,000 | 85,000 | 115,000 | |
|
|
|
|
|
|
| Output - High Fire (Btu)1 | 54,400 | 68,000 | 92,000 | |
|
|
|
|
|
|
| Input - Low fire (Btu) - First Stage1 | 47,600 | 59,500 | 80,500 | |
|
|
|
|
|
|
| Output - Low fire (Btu)1 | 38,080 | 47,600 | 64,400 | |
|
|
|
|
|
|
| AFUE | 80% | 80% | 80% | |
|
|
|
|
|
|
| Temp. Rise | High | |||
|
|
|
|
| |
| Low | ||||
|
| ||||
|
|
|
|
|
|
| Position | All position | All position | All position | |
|
|
|
|
|
|
| Gas Connection | 1/2" NPT | 1/2" NPT | 1/2" NPT | |
|
|
|
|
|
|
| NOX (Ng/J) | <40 | <40 | <40 | |
|
|
|
|
|
|
| ELECTRICAL DATA |
|
|
| |
| Volts, Phase, Herz | 115 / 60 / 1 | 115 / 60 / 1 | 115 / 60 / 1 | |
|
|
|
|
|
|
| Min. / Max. Voltage | 102 / 132 | 102 / 132 | 102 / 132 | |
|
|
|
|
|
|
| Transformer (V.A.) | 40 | 40 | 40 | |
|
|
|
|
|
|
| Min. Time Delay Breaker or Fuse2 | 15 AMP | 15 AMP | 15 AMP | |
|
|
|
|
|
|
| HEAT EXCHANGER |
|
|
| |
| Number of Tubes | 4 | 5 | 7 | |
|
|
|
|
|
|
| Approximate BTUs / Tube | 17,000 | 17,000 | 17,000 | |
|
|
|
|
|
|
| Tube Diameter (inches) | 1.5 | 1.5 | 1.5 | |
|
|
|
|
|
|
| Number of Passes | 4 | 4 | 4 | |
|
|
|
|
|
|
| BLOWER PERFORMANCE DATA |
|
|
| |
| A/C Cooling Max. (CFM) @.5 static | 1,350 | 1,550 | 1,750 | |
|
|
|
|
|
|
| Blower Wheel | 10 x 8 | 10 x 10 | 11 x 10 | |
|
|
|
|
|
|
| A/C Cooling Tons @ .5 esp | 1.5 - 3.5 | 2 - 4 | 2.5 - 5 | |
|
|
|
|
|
|
| Motor Speed | Variable | Variable | Variable | |
|
|
|
|
|
|
| CABINET DIMENSIONS |
|
|
| |
| Cabinet Width (inches) | 17 1/2 | 20 1/2 | 22 | |
|
|
|
|
|
|
| Cabinet Height (inches) | 35 | 35 | 35 | |
|
|
|
|
|
|
| Cabinet Depth (inches) | 28 1/4 | 28 1/4 | 28 1/4 | |
|
|
|
|
|
|
| Volume (Cubic Feet) | 10.28 | 12.05 | 12.93 | |
|
|
|
|
|
|
| PACKAGING DIMENSIONS |
|
|
| |
| Package Width (inches) | 21 1/4 | 24 1/4 | 25 3/4 | |
|
|
|
|
|
|
| Package Height (inches) | 37 3/4 | 37 3/4 | 37 3/4 | |
|
|
|
|
|
|
| Package Depth (inches) | 31 3/4 | 31 3/4 | 31 3/4 | |
|
|
|
|
|
|
| Loadability 40’ High Cube Container | 116 | 104 | 100 | |
|
|
|
|
|
|
| Packaged Weight (lbs) | 132 | 146 | 163 | |
|
|
|
|
|
|
NOTES:
1.Values based on Natural Gas usage
2.Important: It is required to size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes
2
Specifications subject to change without notice.