Outdoors
InstallationNotes
• Unit is normally balanced on HIGH speed with the furnace blower ON.
• Weatherhood arrangement is for drawing purposes only.Six feet (2m) minimum separation
isrecommended. The Weatherhood must also be 18" (460mm) above grade minimum.
• The airflow must be confirmed on site using the balancing procedures found in this manual.
Dampersfor
balancing
airflows
Staleair from various
parts of home.
i.e. bathrooms (if required)
Kitchens (if required)
Fresh air tohouse -
mainliving areas.
bedrooms, livingroom,
rec.room, etc.
Fully Dedicated Installation Diagrams
Fully Dedicated System
This is a stand alone HRV/ERV system which
is not connected to a force air system. Stale air
isdrawn from key areas of the home (bathroom,
kitchen) w hile fresh air is s upplied to main
livingareas.
KeyPoints
TheHRV/ERV must be balanced.
Theduct configuration may change
dependingon the HRV/ERV model. See
specificationsfor your unit.
Checklocal codes / authority having
jurisdictionfor acceptance.