8.Insert lamp through hole until lamp cannot be inserted any further. (See Figure 16)

9.Swing the swivel bracket over end of lamp. Hand-tighten the wing nut on stud. (See Figure 17) Be careful not to over tighten the wing nut. The porcelain at the lamp base may crack when over tightened.

Figure 16

Figure 17

10.Plug ballast plug into end of lamp. (See Figure 18)

11.Snap cover onto the unit base. Close the cover and tighten cover screw. (See

Figure 19 & 20)

Figure 18

12.

Plug the power cord into a standard electrical outlet.

 

 

Figure 19

 

NOTE: Seal the joints and seams of the plenum near the mounting

 

location to reduce any direct viewing of light. (See Figure 1)

 

13.

Press the power switch to the ‘ON’ position. (Light on switch should be on indicating power.)

Figure 20

14.Look through view port in the box cover to be sure lamp is working. You should see a blue glow. (The view port is covered with a plastic lens that blocks the UVC rays.)

15.If the lamp is not glowing, follow steps 8-14 again. If lamp still does not glow, contact technical support at 1-252- 522-3031 for further assistance.

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.