V.MAINTENANCE

V.MAINTENANCE

1.Inspect and clean lamp at least every 6 months.

2.Replace your UV-Aire™ Air Purifying System lamp once a year to maintain the lamps maximum output intensity. The lamp should operate continuously for maximum lamp life and light effectiveness.

VI. LAMP REPLACEMENT PROCEDURE

VERY IMPORTANT: Turn switch on unit to ‘OFF’ position and unplug unit from outlet.

1.Loosen the cover screw on the side of the unit and open cover.

2.Unplug ballast plug from end of lamp.

3.Loosen the wing nut on swivel bracket and rotate the bracket clockwise.

4.Slide lamp out carefully.

NOTE: When replacing the lamp, always wipe off lamp before installing.

5.Insert the lamp through the mounting hole and secure the lamp by rotating the swivel bracket counter-clockwise into position and secure by tightening wing nut. Be careful not to over tighten the wing nut.

NOTE: UV lamps contain a small amount of mercury, like a typical fluorescent lamp. Check with your local waste management authority for local disposal or recycling requirements. According to the EPA’s Universal Waste Rule, these types of lamps may be disposed of into household waste.

6.Attach the ballast plug onto the end of the lamp.

7.After replacing lamp, make sure a new Lamp Replacement Label (supplied with lamp replacement) is applied to the housing and dated with the date of installation.

VII. TROUBLESHOOTING GUIDE

1.If the lamp does not light up, replace the lamp.

2.If the lamp still does not light up after replacing the lamp, replace ballast.

VIII. REPLACEMENT PARTS LIST

 

MODEL

 

LAMP

BALLAST

 

 

(Field Controls Part Number)

(Field Controls Part Number)

 

 

 

 

UV-12

46365401

46365508

 

 

 

 

 

UV-18

46365402

46365509

 

 

 

 

 

For replacement parts, contact your local heating service company. Any questions, please contact Field Controls at:

Phone: 252-522-3031

Fax: 252-522-0214

Email: sales@fieldcontrols.com

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your

hands.