Field Controls UV-18HPC, UV-28C, UV-18C, UV-12HPC I.Indication For Use, Ii.General Information

Models: UV-18HP UV-28C UV-12C UV-18C UV-18HPC UV-28HPC UV-28HP UV-12HPC UV-28 UV-12HP

1 12
Download 12 pages 48.09 Kb
Page 2
Image 2
I.INDICATION FOR USE

I.INDICATION FOR USE

This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition.

II.GENERAL INFORMATION

There are different size units available, depending on the square footage of your home. See chart below for determining your homes needs.

 

 

 

Minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

Max Air

 

 

Lamp Intensity at 1

 

 

Recommended

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

Duct

 

Volts

 

 

Amps

 

 

Hz

 

 

Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp °F

 

 

meter

 

 

Max Sq. Feet

 

 

 

 

Width

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UV-12C

9

120

 

0.5

 

60

 

30

 

190°

 

 

37 μW/cm2

1500

 

 

UV-18C

14

120

 

0.5

 

60

 

30

 

190°

 

 

73 μW/cm2

2000

 

 

UV-28C

22

120

 

1.1

 

60

 

60

 

150°

 

 

105 μW/cm2

3000

 

 

UV-28

22

120

 

1.1

 

60

 

60

 

150°

 

 

105 μW/cm2

3000

 

 

UV-12HP

9

240

 

0.5

 

60

 

30

 

190°

 

 

37 μW/cm2

1500

 

 

UV-18HP

14

240

 

0.5

 

60

 

30

 

190°

 

 

73 μW/cm2

2000

 

 

UV-28HP

22

240

 

1.1

 

60

 

60

 

150°

 

 

105 μW/cm2

3000

 

 

UV-12HPC

9

240

 

0.5

 

60

 

60

 

190°

 

 

37 μW/cm2

1500

 

 

UV-18HPC

14

240

 

0.5

 

60

 

30

 

190°

 

 

73 μW/cm2

2000

 

 

UV-28HPC

22

240

 

1.1

 

60

 

30

 

150°

 

 

105 μW/cm2

3000

 

The UV-12C,18C,28C,12HPC,18HPC, and 28HPC units are equipped with a circuit board to monitor the operation of the UV lamp; it indicates the operation of the lamp through an LED indicator light mounted on the cover of the unit. The circuit board indicates good operation of the lamp by a continuous “GREEN” color on the LED light. After 8,320 hours of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous “YELLOW” color on the LED light and the internal alarm will beep every 15 minutes. After 9,000 hours of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous “RED” color on the LED light and the internal alarm will beep every 5 minutes. The board also checks if the UV lamp is burned out. If the lamp is burned out, the circuit board will indicate this by a continuous “RED” color on the LED and the internal alarm will beep every 5 minutes.

WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc., always turn all power OFF and have unit unplugged. Electrical shock can cause personal injury or death. Never expose eyes or skin to direct UVC light from any source.

II.GENERAL INFORMATION WARNING: To prevent water damage or electric shock, do not mount unit under a humidifier.

Manual background WARNING: Designed for a closed duct system. Do not mount near a supply or a return air opening.

WARNING: This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.). For use on gas fired, oil fired, electric and split system heat pump forced air systems*. This product is NOT designed to be mounted outside on gas fired or heat pump packaged units**.

*Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units.

**Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your

hands.