FTLX1461E2 Product Specification – October 2008

IV. Optical Characteristics

(VCC5 = 4.75 V to 5.25 V, VCC3 = 3.14 V to 3.47 V, VCC aps = 1.152 V to 1.248 V, TC = 0°C to 70°C)

 

Parameter

Symbol

 

Values

 

Unit

 

min.

typ.

max.

 

Transmitter

 

 

 

 

 

 

Launch Power in OMA minus TDP

PO-OMA

–5.2

 

 

dBm

 

Average Launch Power

PO-Avg

–8.2

 

0.5

dBm

 

Center Wavelength Range

λC-Tx

1290

 

1330

nm

 

Spectral Width (-20 dB)

σI

 

 

0.6

nm

 

Side Mode Suppression Ratio

SMSR

30

 

 

dB

 

Extinction Ratio

ER

3.5

 

 

dB

 

Relative Intensity Noise12OMA

RIN

 

 

–128

dB/Hz

 

Optical Modulation Aplitude (OMA)

OMA

–5.2

 

 

dBm

 

Transmitter and Dispersion Penalty

TDP

 

 

3.2

dB

 

Average Launch Power of OFF

PO-OFF

 

 

–30

dBm

 

Transmitter

 

 

 

 

 

 

Optical Return Loss Tolerance

ORLT

 

 

12

dB

 

Transmitter Reflectance

REFTX

 

 

–12

dB

 

Eye Mask Definition

 

According to IEEE 802.3ae

 

 

Receiver

 

 

 

 

 

 

Stressed Receiver Sensitivity in OMA

PIN-S

 

 

–10.3

dBm

 

Rx Sensitivity in OMA1)

PIN-O

 

 

–12.6

dBm

 

Average Receiver Power1)

PIN

-14.4

 

0.5

dBm

 

Receiver Damage Power

PIN-dmg

 

 

1.5

dBm

 

Signal Detect Assert Level

PLOSa

 

 

–13

dBm

 

Signal Detect Hysteresis

PLOSh

1

 

 

dB

 

Receiver Reflectance

REFRX

 

 

–12

dB

 

Receive Electrical 3dB Upper Cutoff

FC

 

 

12.3

GHz

 

Frequency

 

 

 

 

 

 

Center Wavelength Range

λC-RX

1260

 

1355

nm

 

Stressed Signal Calibration

 

 

 

 

 

 

Vertical Eye Closure Penalty

 

2.2

 

 

dB

 

Stressed Eye Jitter

 

0.3

 

 

UIpp

1)Average Receiver Power (min), which is defined for an ideal input signal, is informative only.

V. General Specifications

Optical Interface Standard Specifications

 

Differential Group Delay

Operating Range 1) (meters)

Standard

Maximum (ps)

B1.1 SMF

10

2 to 10,000

B1.3 SMF

10

2 to 10,000

Notes:

1) Operating range as defined by IEEE standards. Longer reach possible depending upon link implementation.

© Finisar Corporation – October 2008

Rev B