| Operation | 1 3 | |||
|
| Troubleshooting |
|
|
|
|
|
|
|
|
|
|
|
|
| Problem | Possible Cause |
|
|
|
|
|
|
|
|
|
|
|
| Smoke Enters Room | • Cold Air Blockage - burn a piece of newspaper to |
|
|
|
|
| During | establish a draft. |
|
|
|
|
|
| • |
|
|
|
|
|
| ring above the door all the way out. |
|
|
|
|
|
| • Close the doors - if the flame is not getting enough air, |
|
|
|
|
|
| first make sure the air control is open (all the way left). If |
|
|
|
|
|
| additional air is needed, a small crack in the door is all |
|
|
|
|
|
| that is needed. |
|
|
|
|
|
|
|
|
|
|
|
| Kindling Does Not Start - | • Cold Air Blockage - burn a piece of newspaper to |
|
|
|
|
| Fire Smolders | establish a draft. |
|
|
|
|
|
| • Not enough starter paper - use additional newspaper if |
|
|
|
|
|
| necessary. |
|
|
|
|
|
| • |
|
|
|
|
|
| ring above the door all the way out. |
|
|
|
|
|
| • Not enough air - first make sure the air control is open |
|
|
|
|
|
| (all the way left). If additional air is needed, a small crack |
|
|
|
|
|
| in the door is all that is needed. |
|
|
|
|
|
|
|
|
|
|
|
| Smoke Enters Room | • |
|
|
|
|
| While | above the doors) using gloves or a tool before opening |
|
|
|
|
|
| the door. |
|
|
|
|
|
| • Insufficient Draft - Chimney height and outside |
|
|
|
|
|
| conditions can negatively affect draft. In these cases a |
|
|
|
|
|
| small amount of smoke may enter the home. Adding |
|
|
|
|
|
| more pipe or a |
|
|
|
|
|
|
|
|
|
|
|
| Fireplace Does Not Burn | • Wood is Wet - see the section "Selecting Wood" on |
|
|
|
|
| Hot Enough | page 12 for details on wood. |
|
|
|
|
|
| • Insufficient Draft - Chimney height and outside |
|
|
|
|
|
| conditions can negatively affect draft. In these cases |
|
|
|
|
|
| the fire may burn slowly. Adding more pipe or a draft- |
|
|
|
|
|
| inducing cap may help. |
|
|
|
|
|
| • Air Control is Not Wide Open - Make sure the air control |
|
|
|
|
|
| is all the way to the left. Slide the control back and forth |
|
|
|
|
|
| rapidly to insure the control is not stuck. |
|
|
|
|
|
|
|
|
|
|
|
| Blower Does Not Run | • Fireplace is Not Up to Temperature - This is normal. |
|
|
|
|
|
| The blower will come on when the fireplace is hot - |
|
|
|
|
|
| usually 15 to 30 minutes. |
|
|
|
|
|
| • Electricity is Cut to the Blower - Check the household |
|
|
|
|
|
| breaker or fuse to make sure it is operable. |
|
|
|
|
|
|
|
|
|
|
|
| Faceplate is Cold | • This is Normal - The air leading into the firebox comes |
|
|
|
|
|
| from the exterior. In some cases this air comes into the |
|
|
|
|
|
| firebox and exits up the chimney. This will not damage |
|
|
|
|
|
| the fireplace nor cool the home much. |
|
|
|
|
|
|
|
|
|
|
|
| Fireplace Does Not Burn | • The doors are not sealing - See the section "Check the |
|
|
|
|
| Overnight | Door Seal, Adjust if Necessary" on page 16 for details. |
|
|
|
|
|
|
|
|
|
|
Travis Industries | 9 3 5 0 8 0 9 4 | 2 2 0 6 0 2 |