ARCHITECTURAL AND ENGINEERING SPEC
The carbon monoxide alarm shall be a First Alert Model CO400 (no display) or a CO410 (digital display) and shall provide at a minimum the following features and functions:
1.An electrochemical CO sensor.
2.The unit shall have a digital display with peak CO memory feature (CO410 only).
3.Powered by supervised 2 AA alkaline batteries and a solid state piezo horn rated at 85dB at 10 ft.
4.The CO sensor is adjusted not to detect CO levels below 30 PPM and will not alarm when exposed to constant levels of 30 PPM for 30 days. It will alarm at the following levels: 400 PPM CO between 4 and 15 minutes, 150 PPM CO between 10 and 50 minutes and 70 PPM CO between 60 and 240 minutes.
5.A visual red LED
6.A full function test button should check all alarm functions by simulating a CO condition, causing the unit to alarm.
7.Two Silence features - Low Battery Silence: Silence low battery chirp for up to 8
hours. Alarm Silence: Temporarily silence unwanted nuisance alarms.
8.The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and relative humidity between 10% and 95%.
9.The unit shall contain mounting hardware and shall be listed for wall mounting.
10.The unit shall at a minimum meet the requirements of UL2034, NFPA 720, NFPA 101, ICC.
INSTALLATION OF ALARM
Installation of this alarm must conform to NFPA 720. Always check your local building codes. Follow all instructions for placement as outlined in the user’s manual.
THE PARTS OF THESE CO ALARMS
CO400BCO410B
2 |
|
| 6 |
1 | 2 | 7 | 1 |
|
5 |
| 3 | 5 | 3 |
| 4 |
|
| 4 |
1. | Open door here |
| 5. | (Behind Cover) Alarm Horn |
2. | Test/Silence button |
| 6. | Peak Level Button (CO410B only) |
3. | POWER/ALARM Light |
| 7. | Digital Display (CO410B only) |
4. | AA Battery Compartment |
|
|
|
TECHNICAL SPECS
Alarm Dimensions: | 3.3”H x 4.8"L x 1.5"D |
Weight: | 5.5 oz. (CO400B) |
| 6.2 oz. (CO410B) |
|
|
Operating Voltage: | Two 1.5V AA Alkaline Batteries |
|
|
Temperature Range: | 40°F (4°C) to 100°F (38°C) |
|
|
Humidity Range: | 10% to 95% relative humidity (RH) |
|
|
Audio Alarm: | 85dB at 10 feet |
|
|
Test/Silence: | Electronically simulates CO conditions, causing the unit to |
| alarm or temporarily silence the alarm |
Alarm Reset: | Automatic when explosive gas and/or CO clears |
|
|
CO Sensor: | Electrochemical |
|
|
Indicator Lights/Sounds: |
|
DC Power: | Intermittent red Light |
CO Alarm: | Audio Alarm (4 beeps, pause, 4 beeps), rapidly |
| flashing red light |
Digital Display: | (CO410B only) Displays battery level, CO levels in parts per |
| million (PPM), Peak CO level |
|
|
Listing: | Listed to UL 2034 Standard |
SHIPPING SPECS:
Individual Carton Dimensions | 5.813 ”L x 2.938”W x 3.438”H |
| |
| Weight | 0.43 lbs. (CO400B) |
|
|
| 0.48 lbs. (CO410B) |
|
| Cube | 0.034 ft3 |
|
| UPC | 0 29054 00074 3 (CO400B) |
|
|
| 0 29054 00097 2 (CO410B) |
|
|
|
|
|
Master Carton Dimensions | 7.4”L x 5.4”W x 6.1”H |
| |
Master Pack | 6 |
| |
| Weight | 2.92 lbs. (CO400B) |
|
|
| 3.21 lbs. (CO410B) |
|
| Cube | 0.14 ft3 |
|
| I2 of 5 | 600 29054 00074 5 (CO400B) |
|
|
| 600 29054 00097 4 (CO410B) |
|
|
|
|
|
Pallet Information |
|
| |
| Cases per Layer | 45 |
|
| Number of Layers | 6 |
|
| Cases per Pallet | 270 |
|
| Units per Pallet | 1,620 |
|
| Cube | 49.6 ft3 |
|
| Weight | 788 lbs. (CO400B) |
|
|
| 867 ibs. (CO410B) |
|
|
|
|
|
©2009 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL
First Alert is a registered trademark of the First Alert Trust
brkelectronics.com BRK is a registered trademark of BRK Brands, Inc.
CM2927