TO ENTER PROGRAMMING MODE:
Local programming requires the use of an alpha keypad connected to the keypad terminals on the control.
1. | POWER UP, then depress | [✱] and [#] both at once, within 50 seconds of powering up. | ||
| OR |
|
|
|
2. | Initially, key: Installer Code | (default = 4112) plus 8 + 0 + 0. |
| |
| ✱ |
| To Exit Programming Mode | paragraph below. |
| (if98 was used to exit previously, see |
Data Field Programming Procedures
Task | Procedure |
|
|
Go to a Data Field | Press [ ∗ ] + [Field Number], followed by the required entry. |
| |
Entering Data | When the desired field number appears, simply make the required entry. When the last | ||
| entry for a field is entered, the keypad beeps three times and automatically displays the | ||
| next data field in sequence. |
|
|
| If the number of digits that you need to enter in a data field is less than the maximum | ||
| digits available (for example, the phone number fields *41, *42), enter the desired data, | ||
| then press [ ∗ ] and the next data field number to be programmed to end the entry. | ||
Review a Data Field | Press [#] + [Field Number]. |
|
|
| Data will be displayed for that field number. No changes will be accepted in this mode. | ||
|
|
|
|
Deleting an Entry | Press [ ∗ ] + [Field Number] + [ | ∗ ]. (Applies only to fields | ∗ |
| programming fields) |
|
|
|
|
|
|
Interactive Mode Programming ( | ∗ 56, *57, | ∗ 58, ∗ 79, ∗ 80, ∗ 81, ∗ 82) | ||
Press | [✱] + [Interactive Mode No.] | (for example, | ✱56). The alpha display keypad will display the first of a series of prompts | |
requesting entries. |
|
|
| |
Interactive Mode |
| Used to Program | ||
✱56 Zone Programming | Zone characteristics, report codes, alpha descriptors, and serial numbers for 5800 | |||
|
|
| RF transmitters. | |
✱57 Function Key Programming | Unlabeled keypad keys (known as ABCD keys) for special functions | |||
|
|
| ||
✱58 Zone Programming | Same options as *56 mode, but with fewer prompts. Intended for those familiar with | |||
(Expert mode) |
| this type of programming, otherwise *56 mode is recommended. | ||
|
|
| ||
✱79 Output Device Mapping | Assign module addresses and map individual relays/powerline carrier devices | |||
|
|
|
| |
✱80 | Output Programming | 4229 or 4204 Relay modules, Powerline Carrier devices, or | ||
✱81 | Zone List Programming | Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc. | ||
|
|
|
|
|
✱82 | Alpha Programming | Zone alpha descriptors |
| |
|
|
|
|
|
INITIALIZE DOWNLOAD and RESET DEFAULTS
✱96 Initializes download ID and subscriber account number.
✱97 Sets all data fields to original factory default values.
TO EXIT PROGRAMMING MODE: |
|
|
|
|
|
| |
✱98 | Exits programming mode and | prevents |
| Installer Code | + 8 | + 0 + 0 . To reenter the programming mode, | |
| the system must be powered down, then powered up, then press both |
| [✱] and [#]at same time within 50 seconds | ||||
| of powering up (method 1 described above), UNLESS | Local Lockout (in field *91) is enabled. | If so, | ||||
| programming mode is permitted | only | by | Installer Code + 8 + 0 + 0 (method 2 described above). | |||
✱99 | Exits programming mode and | allows | Installer Code + 8 | + 0 | + 0 or method 1 above. |
Special Messages
OC = OPEN CIRCUIT (no communication between Keypad and Control).
EE or ENTRY ERROR | = ERROR (invalid field number entered; |
After powering up, AC, dI This will revert to a “ Ready
delay by pressing | [#] + [0]. |
(disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds. ” message in approximately 1 minute, which allows PIRS, etc. to stabilize. You can bypass this
IfE4 or E8 appears, more zones than the expansion units can handle have been programmed. Correct the programming and then completely