NOTE: Entry of a number other than one specified will give unpredictable results.

For fields *43-*46:Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter[] as the fourth digit if a 3-digit account number (for 3+1 dialer

reporting format) is used. Enter 0 as the first digit of a 4-digit account number for Nos. 0000-0999. Exit field by pressing

(and press next field number) if only 3

digits are used. E.g., For Acct.

B234

, enter:

#+11 2 3 4

43 PARTITION 1 PRIMARY SUBS. ACCT. No.

 

 

See box above for entries. To clear entries

[FFFF]

from field, press

*43 *.

 

 

44 PARTITION 1 SECONDARY SUBS. ACCT. No.

45 PARTITION 2 PRIMARY SUBS. ACCT. No.

46 PARTITION 2 SECONDARY SUBS. ACCT. No.

[FFFF]

Manual background [FFFF]

Manual background [FFFF]

See box above for entries. To clear entries from field, press *44*.

See box above for entries. To clear entries from field, press *45 *.

See box above for entries. To clear entries from field, press *46 *.

47 PHONE SYSTEM SELECT

[1]

If Cent. StaIS. NOT

on a WATS line:

0=Pulse Dial; 1=Tone Dial;

 

 

if Cent. Sta.IS on

a WATS line:

 

2 = Pulse Dial ; 3 = Tone Dial

48 REPORT FORMAT

primary

49 SPLIT/DUAL REPORTING

50 15 SEC DIALER DELAY (BURG)

53 SESCOA/RADIONICS SELECT

54 DYNAMIC SIGNALING DELAY

secondary

[0]

[0]

[0]

[0]

[70]0 = 3+1, 4+1 ADEMCO L/S STANDARD

1 = 3+1, 4+1 RADIONICS STANDARD

2 = 4+2 ADEMCO L/S STANDARD

3 = 4+2 RADIONICS STANDARD

6 = 4+2 ADEMCO EXPRESS

7 = ADEMCO CONTACT ID® REPORTING

8 = 3+1, 4+1 ADEMCO L/S EXPANDED

9 = 3+1, 4+1 RADIONICS EXPANDED

0

= Disable (Backup report only)

 

 

 

 

Primary Phone No.

 

 

Second

Phone No.

 

 

 

1

= Alarms, Restore, Cancel

 

Others

 

2

= All except Open/Close, Test

Open/Close,

Test

3

= Alarms, Restore, Cancel

 

All

 

 

4 = All except Open/Close, Test

All

 

5

= All

 

 

All

0

 

 

; 1 = yes

= no UL: must be “0”

 

 

 

 

 

 

 

 

0= Radionics (0-9, B-F)

1= SESCOA (0-9 only reporting) Select “0” for all other formats.

Delay selectable from 0 to 225 secs in 15-sec increments.

0 = no delay (both signals sent), 1 = 15 secs, 2 = 30 secs, etc. UL: must be “0”

55 DYNAMIC SIGNALING PRIORITY

[0]

0 = Primary Dialer first; 1 = Long Range Radio

first.

 

TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (

 

 

 

 

59 – 76, & 89):

 

 

For 3+1 or 4+1 Standard Format:

Enter a code in the

 

firstbox: 1–9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F.

A 0 (

not

#+10) in the firstbox will disable a report. A 0 (

 

not #+10) in the second

box will result in automatic advance to the next field.

 

For Expanded or 4+2 Format:

Enter codes in

both

boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.

 

 

A 0 (

not

#+10) in the second

box will eliminate the expanded message for that report. A 0 (

not #+10) in both boxes will disable the report.

For Ademco Contact ID® Reporting:

Enter any digit (other than 0) in the

firstbox, to enable zone to report (entries in the

second

boxes are ignored).

 

 

 

 

 

 

 

 

 

A 0 (

not

#+10) in the firstbox disables the report.

 

 

UL: see installation instructions for requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM STATUS REPORT CODES (

59– 68)

59

EXIT ERROR REPORT CODE

 

60

TROUBLE REPORT CODE

 

61

BYPASS REPORT CODE

 

62

AC LOSS REPORT CODE

 

63

LOW BAT REPORT CODE

 

64

TEST REPORT CODE

 

65

OPEN REPORT CODE

 

[0]See box above.

[00]

See box above.

 

 

 

[00]

See box above.

 

 

 

 

[00]

See box above.

 

 

 

 

[00]

See box above.

 

 

 

 

[00]

See box above. Use Scheduling mode to set periodic test reports.

 

 

 

[0,0,0]

See box above.

 

 

 

Part. 1 Part. 2 Common

66 ARM AWAY/STAY RPT CODE

Away Stay

Part. 1

[0,0,0,0,0,0]

See box above.

Away Stay

Away Stay

Part. 2

Common

4