First Alert SA520B First Alert, Technology, Cost Effective Retrofit & Remodel Solutions, SCO500B

Models: SA520B

1 2
Download 2 pages 32.58 Kb
Page 2
Image 2
Cost Effective Retrofit & Remodel Solutions

Cost Effective Retrofit & Remodel Solutions

• Wireless interconnect technology eliminates the need to pull wires
through existing walls
• Save an average of between $150 - $200** per alarm when

compared to retrofitting hardwired alarms in existing walls or ceilings

First Alert® • Wireless interconnect technology eliminates the need to pull wires

Technology

All through existing walls alarms include these quality innovative features:
• Faster job turnaround - 4X more jobs completed increases your profits

• Photoelectric sensing technology saves maintenance calls with fewer nuisance alarms.

RF Interconnect: Reliable and secure radio frequency communication between alarms. 915 MHz frequency with 65,000 security codes and 3 channel frequency hopping.

Photoelectric Technology: Helps reduce nuisance alarms, especially around kitchens and baths which are more prone to nuisance alarms from cooking smoke and shower steam.

Test/Silence Button: Tests alarm functions and battery. Silences unwanted alarms. Two silence features - Temporarily silence low battery chirp for up to 8 hours before replacing battery or silence unwanted alarm for several minutes.

Perfect Mount: mounting bracket keeps alarm secure over a wide rotation range to allow for perfect alignment.

Putting the Innovation in Renovation

When it comes to alarm renovation and retrofit projects, choices have been limited. Installing battery operated alarms and sacrificing interconnectability or investing in the time and labor to retrofit hardwired alarms have been the only options available.* Until Now! First Alert OneLink eliminates the need to pull wires through existing walls saving time, money and labor.

No matter what your renovation project,

First Alert OneLink provides a cost effective solution:

Home Addition Projects:

Using the First Alert OneLink hardwired "Bridge Unit" (SA520B), simply replace one hardwired alarm in the existing section and add one to the new section. Wireless

Master• Save an average of between $150 - $200** per alarm whenFirst Alert® TechnologyAll  alarms include these quality innovative features:• Faster job turnaround - 4X more jobs completed increases your profitsPutting the Innovation in Renovation Bedroom SCO500BMesh Network Communication Bedroom

Blocked

Manual background Hall Manual background

Optipath 360 Technology™: Patented technology provides 360 degrees of direct access to smoke sensor.

Spread Spectrum Horn Tone: Lower and varying horn frequency makes it easier for elderly with normal age related hearing loss to hear horn. Sweeps through the 2200 - 3400 Hz range.

SCO500B

Wireless Photoelectric

Battery Combination

Smoke & CO Alarm

Dust Cover: Keeps alarm clean during construction.

Latching Features Alarm Latch: Easily identifies initiating alarm even after alarm condition has subsided. Low Battery Latch: Identifies which unit is in low battery condition. Both features activate for up to 15 minutes. (excludes SA520B)

Exclusive!

W I T H L O C AT I O N

technology saves time, material and labor to connect to the existing alarm circuit. Now add standard BRK hardwired alarms as required in the new section and other First Alert OneLink battery alarms in the old section to complete the alarm safety system and bring entire home up to code. All alarms, hardwired and battery, existing and new are now interconnected.

Retrofit Projects:

Property Owners, Facility Managers and Electrical Contractors can all benefit from installing First Alert OneLink alarms for existing retrofit projects. Saving $150 - $200** per alarm and increasing job turnaround 4X are key reasons to consider First Alert OneLink alarms for all of your renovation projects.

Mesh Network Communication

First Alert OneLink alarms operate on a "mesh network"; a

Basement

®

Mesh Network Communication

Exclusive! Voice alarm with programmable location. Programmable with up to 11 locations (ex. “basement”). When alarm sounds (if programmed for basement), it will say, “Warning, Evacuate, Smoke in Basement”. If other First Alert OneLink Voice Warning alarms are located throughout the house they will also signal, “Warning, Evacuate, Smoke in Basement”.

Add additional battery-operated First Alert Manual background Enabled Alarms to create a wireless safety network.

5-year limited warranty.

W I T H L O C AT I O N

W I T H L O C AT I O N

2-way communication format that sends, receives and then re-sends the alarm signals. If the initiating alarm signal is blocked from reaching one of the alarms, the mesh network communication reroutes and re-sends the signal via the other alarms as shown in the illustration. With competitive one-way wireless communication, only the initiating alarm sends a signal which may never be received, leaving the blocked alarm deadly silent.

*Local codes permitting

**Note: Based on average retrofitting costs of time, material and

labor to connect to existing alarm circuit, drywall repairs, painting, etc. Special cases that require conduit, wire mold, concrete drilling, etc. would add additional costs and increase savings.

Master

oom

Bedroom

B

l

ocked

Hall

 

 

 

Basement

Competitive Wireless

One-Way Communication

C0511B

Wireless Battery

Carbon Monoxide Alarm

Easily add CO alarms outside bedrooms and on every level of the home to create a wireless safety network.

5-year limited warranty

SA511B

Wireless Photoelectric Battery Smoke Alarm

Easily add smoke alarms to every bedroom to create a wireless safety network.

10-year limited warranty.

SA520B

Bridge Unit-Wireless Photoelectric

120-Volt AC/DC Hardwired Smoke Alarm

Easily expand an existing interconnected 120V AC system by replacing one alarm in the series with this alarm.

Add additional battery-operated First Alert Manual background Enabled Alarms to expand without wires.

10-year limited warranty.

Page 2
Image 2
First Alert SA520B First Alert, Technology, Cost Effective Retrofit & Remodel Solutions, SCO500B, through existing walls