Fisher & Paykel 60 Installation instructions, Do not use a naked flame to test for leaks

Models: 60

1 32
Download 32 pages 5.18 Kb
Page 12
Image 12
Do not use a naked flame to test for leaks.

10

Installation instructions

After installing the freestanding cooker and connecting the gas supply:

1Using a suitable leak detection fluid solution (e.g. Rocol) check each gas connection one at a time by brushing the solution over the connection.

The presence of bubbles will indicate a leak. If there is a leak, tighten the fitting and then recheck for leaks.

Important!

Do not use a naked flame to test for leaks.

2Adjust the test point pressure or supply pressure to the value that is appropriate for the gas type.

3Test the operation of the appliance:

Turn on the appliance gas controls and light each burner individually and in combination. Check for a well-defined blue flame without any yellow tipping. If any abnormality is evident, then check that the burner cap is located properly and the injector nipple is aligned correctly.

Check the minimum burner setting by quickly rotating the gas control knob from the maximum to the minimum position. The flame must not go out. If you need to adjust the setting, see ‘Adjusting the minimum burner setting’ following.

Important!

This appliance IS NOT SUITABLE for installation with a hose assembly.

Plug

Fig. 6 Adjusting the connection pipe

Fig. 7 Gas supply inlets

Page 12
Image 12
Fisher & Paykel 60 installation instructions Installation instructions, Do not use a naked flame to test for leaks