12
Installation instructions
Adjusting the minimum burner setting
Check whether the flame spreads to all burner ports when the burner is lit with the gas tap set to the minimum position. If some ports do not light, increase the minimum gas rate setting.
Check whether the burner remains lit even when the gas tap is turned quickly from the maximum to the minimum position. If the burner does not remain lit, increase the minimum gas rate setting.
To adjust the minimum gas rate setting: Turn on the burner.
Turn the tap to the MINIMUM position. Take off the knob.
With a small flat screwdriver turn the screw to the correct regulation.
Note: for LPG gas, the regulation screw is normally tightened up.
Fig. 10 Adjusting the minimum burner setting
Table for the choice of injectors
| Natural gas | LPG gas | ||||
|
|
|
|
|
|
|
Test Point Pressure [kPa] |
| 1.0 |
| 2.75 | ||
|
|
|
|
|
|
|
| Injector |
| Gas | Injector |
| Gas |
BURNER | Orifice Dia. |
| Consumption | Orifice Dia. |
| Consumption |
|
|
|
|
|
| |
| [mm] |
| [MJ/h] | [mm] |
| [MJ/h] |
|
|
|
|
|
|
|
Auxiliary | 0.85 |
| 3.60 | 0.53 |
| 3.60 |
|
|
|
|
|
|
|
1.12 |
| 6.30 | 0.70 |
| 6.30 | |
|
|
|
|
|
|
|
1.65 |
| 13.30 | 0.95 |
| 11.90 | |
|
|
|
|
|
|
|