Fisher & Paykel ADN20x36 installation instructions Dcs By Fisher & Paykel Access Doors Adn

Models: ADN20x24 ADN20x48 ADN20x36 ADN20x30

1 4
Download 4 pages 17.74 Kb
Page 1
Image 1
DCS BY FISHER & PAYKEL ACCESS DOORS ADN

DCS BY FISHER & PAYKEL ACCESS DOORS ADN

installation instructions

ACCESS DOOR SPECIFICATIONS:

47-15/16”

35-15/16”

21-7/8”

MODEL: ADN20x48

MODEL: ADN20x36

30”

21-7/8”

MODEL: ADN20x30

24”

1-1/4”

 

 

 

 

 

 

 

 

 

 

MODEL: ADN20x24

 

5/16”

 

15/16”

 

2-1/8”

 

Anchor hole

4-1/4”

(Ø 1/4”)

2”

SIDE VIEW

CUTOUT SPECIFICATION

Vent*

Vent*

 

 

 

 

 

 

A

B

Vent*

 

 

 

 

 

 

90º

 

 

ACCESS DOOR

A

B

MODELS

(-0”, +1/8”)

(-0”, +1/8”)

ADN20x48

46"

20”

 

 

 

ADN20x36

34"

20”

 

 

 

ADN20x30

28"

20”

 

 

 

ADN20x24

22"

20”

 

 

 

NOTE: The cutout of each corner should be 90° angle in order for the access doors to fit properly. * Island installation to use minimum of 3 vents providing 10 sq. in. per vent (typical).

INSTALLATION INSTRUCTIONS

1.Slide frame into opening (see cutout dimensions in chart above).

2.Check for proper alignment.

3.Using the four slotted holes in the frame as a guide, pre drill four pilot holes on the left & right sides of your island. Secure the unit using screws and anchors suited for the type of cabinet material.

4.Install the access door and check for proper alignment of doors and frame.

Page 1
Image 1
Fisher & Paykel ADN20x36 installation instructions Dcs By Fisher & Paykel Access Doors Adn, Access Door Specifications