Fisher & Paykel CG604 Installation instructions, Dimensions and clearances

Models: CG604

1 32
Download 32 pages 49.1 Kb
Page 8
Image 8
Installation instructions

6

Installation instructions

Dimensions and clearances

This cooktop has been designed and constructed in accordance with the following codes and specifications:

AGA101 (AS 4551) Approval Requirements for Domestic Gas cooking appliances

AS/NZS 60335-1 General Requirements for Domestic electrical appliances

AS/NZS 60335-2-6 Particular Requirements for Domestic electrical cooking appliances

AS/NZS 1044 Electromagnetic Compatibility Requirements.

The installation shall comply with the dimensions in Figs. 1 and 2, bearing in mind the fol- lowing requirements:

A minimum clearance of 20 mm has to be kept between the base of the cooktop and the top of an underbench appliance or a shelf. To ensure this clearance, mount the spacers supplied with the appliance, as shown in Fig. 3.

Overhead clearances - In no case shall the clearance between the highest part of the cooktop and a range hood be less than 600 mm, or for an overhead exhaust fan, 750 mm. Any other downward-facing combustible surface less than 600 mm above the highest part of the cook- top shall be protected for the full width and depth of the cooking surface area in accordance with local regulations in force. However, in no case shall this clearance to any surface be less than 450 mm.

Side clearances - Where the distance from the periphery of the nearest burner to any vertical combustible surface is less than 200 mm, the surface shall be protected in accordance with local regulations in force to a height of not less than 150 mm above the cooktop for the full dimension (width or depth) of the cooking surface area.

Where the distance from the periphery of the nearest burner to any horizontal combustible surface is less than 200 mm, the horizontal surface shall be more than 10 mm below the surface of the cooktop, or the horizontal surface shall be above the trivets (see requirement for vertical combustible surfaces above).

Protection of combustible surfaces - Local regulations in force specify that, where required, protection shall ensure that the surface temperature of the combustible surfaces does not exceed 65 °C above ambient. To comply with this requirement satisfactorily, fix 5 mm-thick ceramic tiles to the surface or attach fire-resistant material to the surface and cover with sheet metal (minimum thickness 0.4 mm).

500

200

 

560

0

 

–2

580

Dimensions and clearances34

0 2 – 480

60

Fig. 1 Product and cutout dimensions