CLEANING AND CARE

CHARCOAL FILTER

The Charcoal Filter is used for non-vented, re-circulated installations. The filter should be changed every 6 to 12 months depending on use.

To initially install the Charcoal Filter:

1.Disconnect power to the oven at the circuit breaker panel or by unplugging.

2.Remove 3 screws that secure louver.

3.Remove louver by inserting flat edge screw- driver over each tab, depressing the tab down and moving the louver away from unit.

4.Pull louver away from the oven.

5.Remove 2 screws that cover the sensor duct cover.

6.Remove the sensor duct cover.

7.Insert the Charcoal Filter by sliding into position on support tabs.

8.Reattach sensor duct cover and secure with 2 screws.

9.Push louver back into place and gently snap tabs into place by hand. Replace the 3 screws to secure louver.

To change/replace the Charcoal Filter:

1.Disconnect power to the oven at the circuit breaker panel or by unplugging.

2.Remove 3 screws that secure louver.

3.Remove louver by inserting flat edge screw- driver over each tab, depressing the tab down and moving the louver away from unit.

4.Pull louver away from the oven.

5.Remove 2 screws that cover the sensor duct cover.

6.Remove the sensor duct cover.

7.Remove old Charcoal filter; discard.

8.Slide replacement Charcoal Filter into position on support tabs.

9.Reattach sensor duct cover and secure with 2 screws.

10.Push louver back into place and gently snap tabs into place by hand. Replace the 3 screws to secure louver.

Note: Replacement Charcoal Filter can be purchased from Fisher and Paykel. Order part number 247890.

Top tab

Sensor duct cover

Screw

 

Charcoal filter

Screw

Charcoal filter

Screw

Charcoal Filter

Oven light

Bottom tab

 

Louver

34

E

Page 34
Image 34
Fisher & Paykel CMOH30SS manual To initially install the Charcoal Filter, To change/replace the Charcoal Filter