Fisher & Paykel DD24S Parts Supplied, Cavity Preparation, located, Services, damage, Water supply

Models: DD24S

1 8
Download 8 pages 53.19 Kb
Page 3
Image 3
4PARTS SUPPLIED

(2,1) -1- 599625C DD24S installA2 USCA.indd 14/4/09 2:16:35 PM

4PARTS SUPPLIED

Drain hose

Drain hose

Wire clip (1)

Clamp (1)

Top mounting

Phillips

Washer (1)

Moisture protection

support (1)

joiner (1)

 

 

brackets (2)

16 mm

 

tape (1)

 

 

 

 

 

screws (7)

 

(to prevent moisture

 

 

 

 

 

 

 

damage)

Edge Protector (1) (if service hole partition is metal)

If the Drain hose(s) supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hose(s) by 11’ 10” (3.6m). The kit is available from the nearest Fisher & Paykel Authorized Service Agent, or Toll free 1.888.936.7872 or www.fisherpaykel.com.

5 CAVITY PREPARATION

Important!

Be sure the edges of the services hole are smooth or covered. If the services hole is through a metal partition the hole must be protected with the Edge protector supplied to prevent damage to the power cord or hoses.

These marks indicate formed bracket screw locations.

Note: To align drawer front to adjacent cabinetry, the product to countertop clearance can

be increased to 1⁄8” (3 mm).

*Preferred position. If adequate clearance, services hole can be higher.

If hole is higher, ensure drain hose(s) are routed straight into the waste connection.

Water Connection

Recommended HOT (Maximum 140°F/60°C).

Supplied hose to suit 3/8” (9 mm) male compression fitting.

If no side partition, use a brace for securing.

2” x 4”

damage)5 CAVITY PREPARATIONWater Connection Moisture 3⁄8” protection

(10 mm) tape must be applied.

 

 

 

can

be

located

 

Services

.

Note:

 

 

 

side

of DishDrawer®

either

 

 

 

 

 

 

 

 

 

Water Pressure

Max

Min

Water softener models

1 MPa (145 psi)

0.1 MPa (14.5 psi)

Other models

1 MPa (145 psi)

0.03 MPa (4.3 psi)

Drains will need to be separated to satisfy kosher requirements. We suggest you confirm acceptability with your local rabbi in respect to kosher installations.

max. ø 1 ½” (38 mm)

*

*

 

 

max. 17 11⁄16

 

 

(450 mm)

Water supply
Max. distance ofLeft handRight hand

hoses and cord from

side

side

chassis edge

 

 

Drain hose

78 ½”

70 ½”

 

(2000 mm)

(1800 mm)

 

 

 

Inlet hose

64 ¾”

49”

 

(1650 mm)

(1250 mm)

 

 

 

Power cord (excl. plug)

29 ½”

27 ½”

 

(750 mm)

(700 mm)

 

 

 

Left hand

side

Right hand

side

 

 

min. 7 7⁄8

 

 

(200 mm)

 

 

110-120 VAC

Important!

 

Adjacent cabinetry must not

max. 15 A

 

extend above cavity base

 

Page 3
Image 3
Fisher & Paykel DD24S Parts Supplied, Cavity Preparation, located, Services, damage, Water Connection, Water Pressure