DIMENSIONS AND CLEARANCES

DIMENSIONS AND CLEARANCES

PRODUCT AND CUTOUT DIMENSIONS

 

CLEARANCES

 

 

A

 

a

B

 

 

C

 

b

 

 

manifold

 

g

center line

 

F

G

h

 

gas inlet

 

e

 

H

D

 

E

 

 

i

US

CLEARANCES c

d

f

 c j

A

GC36

GC901/GC901M

36” (914mm)

36” (914mm)

B

21” (533mm)

211/2" (546mm)

C

15/8" (41.5mm)

29/16" (65mm) GC901,

 

 

3" (76mm) GC901M

D191/2" (494mm) [183/8" - 193/4"] 191/2" (494mm) [191/8" - 205/8"] E 341/4" (870mm) [333/8" - 343/4"] 341/4" (870mm) [337/8" - 351/4"]

F

R3/8" (10mm)

R3/8" (10mm)

G

13/16" (30mm)

3/4" (20mm)

H

1" (25mm)

1" (25mm)

CLAMPING DOWN THE COOKTOP

a36" = Minimum horizontal distance between overhead cabinets installed on either side of this appliance.

b30" = Minimum clearance from combustible surface centered above the cooktop.

c13" = Maximum overall depth of overhead cabinetry.

d

18" = Minimum clearance from countertop to overhead cabinetry.

e

4" (GC36) or 11/2" (GC901 & GC901M) = Minimum clearance

f

from cooktop to the left side wall.

1" = Minimum clearance from cooktop to the right side wall.

g

11/2" (GC36) or 11/4" (GC901 & GC901M) = Minimum clearance

h

from cooktop to the rear wall.

21/2" (GC36) or 11/4" (GC901 & GC901M) = Minimum distance

 

from front edge of counter to front edge of appliance.

Place the cooktop into the cutout and tighten it with the supplied clamps. These will cope with the countertop thicknesses 3/4"- 2" when used in the two orientations shown.

Do not over tighten.

3/4" - 2"

Where this reduces the distance between the back edge of the

appliance and the adjacent wall to less than the minimum of

11/2" (GC36) or 11/4" (GC901 & GC901M), this wall must be of

non combustible material (see note below).

i 23/8" (GC36) or 35/16" (GC901 & GC901M) = Minimum clearance

below countertop to any combustible surface.

j 30" = Maximum distance to nearest grounded power outlet

from the center of the cooktop.

The power cord must not touch any hot metal sufaces.

NON COMBUSTIBLE MATERIAL

Recommended non combustible materials are: 1/4" (6mm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015” (0.4mm) stainless steel, 0.024” (0.6mm) aluminium or 0.020” (0.5mm) copper.