DIMENSIONS AND CLEARANCES
PRODUCT AND CUTOUT DIMENSIONS |
| CLEARANCES |
|
| |
A |
| a |
B |
|
|
C |
| b |
|
| |
manifold |
| g |
center line |
| |
F | G | h |
| ||
gas inlet |
| e |
| H | |
D |
| |
E |
|
|
i
US
c
d
f
j
A | GC36 | GC901/GC901M |
36” (914mm) | 36” (914mm) | |
B | 21” (533mm) | 211/2" (546mm) |
C | 15/8" (41.5mm) | 29/16" (65mm) GC901, |
|
| 3" (76mm) GC901M |
D191/2" (494mm) [183/8" - 193/4"] 191/2" (494mm) [191/8" - 205/8"] E 341/4" (870mm) [333/8" - 343/4"] 341/4" (870mm) [337/8" - 351/4"]
F | R3/8" (10mm) | R3/8" (10mm) |
G | 13/16" (30mm) | 3/4" (20mm) |
H | 1" (25mm) | 1" (25mm) |
CLAMPING DOWN THE COOKTOP
a36" = Minimum horizontal distance between overhead cabinets installed on either side of this appliance.
b30" = Minimum clearance from combustible surface centered above the cooktop.
c13" = Maximum overall depth of overhead cabinetry.
d | 18" = Minimum clearance from countertop to overhead cabinetry. |
e | 4" (GC36) or 11/2" (GC901 & GC901M) = Minimum clearance |
f | from cooktop to the left side wall. |
1" = Minimum clearance from cooktop to the right side wall. | |
g | 11/2" (GC36) or 11/4" (GC901 & GC901M) = Minimum clearance |
h | from cooktop to the rear wall. |
21/2" (GC36) or 11/4" (GC901 & GC901M) = Minimum distance | |
| from front edge of counter to front edge of appliance. |
Place the cooktop into the cutout and tighten it with the supplied clamps. These will cope with the countertop thicknesses 3/4"- 2" when used in the two orientations shown.
Do not over tighten.
3/4" - 2" |
Where this reduces the distance between the back edge of the |
appliance and the adjacent wall to less than the minimum of |
11/2" (GC36) or 11/4" (GC901 & GC901M), this wall must be of |
non combustible material (see note below). |
i 23/8" (GC36) or 35/16" (GC901 & GC901M) = Minimum clearance |
below countertop to any combustible surface. |
j 30" = Maximum distance to nearest grounded power outlet |
from the center of the cooktop. |
The power cord must not touch any hot metal sufaces. |
NON COMBUSTIBLE MATERIAL
Recommended non combustible materials are: 1/4" (6mm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015” (0.4mm) stainless steel, 0.024” (0.6mm) aluminium or 0.020” (0.5mm) copper.
3