Fisher & Paykel GC901 Conversion To A Different Gas Type, Installation Instructions, CG901M only

Models: GC901 GC901M

1 20
Download 20 pages 60.33 Kb
Page 5
Image 5
CG901M only

INSTALLATION INSTRUCTIONS

CG901M only

CONVERSION TO A DIFFERENT GAS TYPE

Burners can be used with NG or LPG, provided that the injector orifices appropriate for the gas delivered are installed.

High altitude orifices are available from Fisher & Paykel USA.

GC36 NG Kit Part No. 530463 LP Kit Part No. 530464 GC901/M NG Kit Part No. 531566 LP Kit Part No. 531567

To change the injector orifices, you will need a 9/32" (7mm) box spanner and a 13/32" (10mm) ring spanner (CG901M only).

1Turn off the main electrical supply.

2Ensure all gas valves are turned off.

3Remove all trivets and burner heads.

4Pull off knobs.

5Remove the 2 screws holding each burner (3 on the wok burner).

6Partially lift the hob and unplug the electrode on the mini- auxiliary burner to allow hob removal. Beware of sharp edges.

WARNING

US

Electrical Shock Hazard

 

Disconnect power before servicing the product.

Failure to do so could result in death or electrical shock.

Changing the

Orifice figure 1

CG901M only

7Unscrew the orifices and replace them with the correct ones. (size numbers are stamped on the side, eg. 70= 0.70mm)

(see figure 1).

8Reset the venturi position aligning the end of the venturi tube with the edge of the slot in the bracket below it. Outermost position for LPG, innermost for NG (see figure 2). Some fine adjustment may be required for local conditions.

9To replace the CG901M hob, repeat steps 3-6 in reverse.

10 Reset the minimum setting. See ‘Minimum Setting’ overleaf.

The label supplied with the orifices should be placed over the existing gas type label to indicate the change.

NG Venturi Position

LPG Venturi Position

Venturi Position

figure 2

5

Page 5
Image 5
Fisher & Paykel GC901 Conversion To A Different Gas Type, Installation Instructions, Electrical Shock Hazard, CG901M only