11
Connecting the power supply cable
Double and Tower oven models
1
Unscrew the screw “A” securing the cover plate “B” behind the oven (Fig. 9).
2
Remove the cover plate “B”.
3
Remove the screws “C” from the cable clamp (Fig. 10).
4
Insert the mains cable into the cable protector “P”.
Type of cable to be used for double models: type V105 for AU and NZ, type H05RR-F for UK
and EU - 3 x 2.5 mm
2
section 230-240 V ~ 4400-4800 W.
Type of cable to be used for tower models: type V105 for AU and NZ, type H05RR-F for UK
and EU - 3 x 4 mm
2
section 230-240 V ~ 6120 W.
5
Connect the phase and earth cables to the mains terminal connection block “D”.
The wires of this appliance must be coloured in accordance with the following code:
GREEN AND YELLOW - EARTH
BLUE - NEUTRAL “N”
BROWN - LIVE “L”
The wire which is coloured GREEN AND YELLOW must be connected to the terminal which is
marked with the letter “E” or by the Earth symbol or coloured GREEN or GREEN AND YELLOW.
The wire which is coloured BLUE must be connected to the terminal which is marked with the
letter “N” or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is marked with the
letter “L” or coloured RED.
6
Refit the cable clamp so that it clamps the outer sleeving of the cable, and screw the screws “C”.
7
Refit the cover plate “B” and fix it with the screw “A”.
Important:
This appliance must be earthed.
Green & Yellow
(Earth)
Brown (Live)
Blue (Neutral)
N
L

A

C
P
D

B

Fig. 9 Fig. 10