Fisher & Paykel OR120 Maintenance instructions, Setting the burner minimum Valves may vary

Models: OR120

1 48
Download 48 pages 8.14 Kb
Page 16
Image 16
Setting the burner minimum (Valves may vary)

14

Maintenance instructions

Setting the burner minimum (Valves may vary)

Check whether the flame spreads to all burner ports when the burner is lit with the gas tap set to the minimum position. If some ports do not light, increase the minimum gas rate setting.

Check whether the burner remains lit even when the gas tap is turned quickly from the maximum to the minimum position. If the burner does not remain lit, increase the minimum gas rate setting.

To adjust the minimum gas rate setting:

Semi-rapid and triple ring wok burners

Light the burner.

Set the gas valve to Semi-rapid and triple ring wok burnersOutside crowns of DUAL burnerManual background position. Remove the knob.

With a thin screwdriver, turn the regulation screw until adjustment is correct (Fig. 9a).

Inside crown of DUAL burner Light the DUAL burner.

Set the gas valve to Manual background position. Remove the knob.

Using a screwdriver, turn the screw “H” until the correct setting is obtained (Fig. 9b).

Outside crowns of DUAL burner

Light the DUAL burner.

Set the gas valve to Manual background position. Remove the knob.

Using a screwdriver, turn the screw “G” until the correct setting is obtained (Fig. 9b).

For G30/G31 gas, tighten the regulation screws completely.

regulation screw

Fig. 9a

H

G

Fig. 9b

Page 16
Image 16
Fisher & Paykel OR120 Maintenance instructions, Setting the burner minimum Valves may vary, Outside crowns of DUAL burner