Fisher & Paykel OR120 installation instructions Installation instructions, Moving the cooker

Models: OR120

1 48
Download 48 pages 8.14 Kb
Page 11
Image 11
Moving the cooker

Installation instructions

Moving the cooker

Important!

9

Two people must always raise the cooker, as shown, to prevent damaging the adjustable feet.

Do not lift the cooker by the door handles. DO NOT DRAG the cooker. Lift the feet clear of the floor.

Fig. 5a Correctly raising the cooker

Ventilation requirements (GB & IE only)

The appliance should be installed in a room or space with an air supply in accordance with BS 5440-2:2000.

For rooms with a volume of less than 5 m3 : permanent ventilation of 100 mm3 free area will be required.

For rooms with a volume of between 5 m3 and 10 m3 : permanent ventilation of 50 cm3 free area will be required unless the room has a door which opens directly to the outside air, in which case no permanent ventilation is required. For rooms with a volume greater than 10 m3 : no permanent ventilation is required.

Fig. 5b Incorrectly moving the cooker

Note: regardless of room size, all rooms containing the appliance must have direct access to the outside air via an openable window or equivalent. Where there are other fuel burning appliances in the same room, BS

5440-2:2000 should be consulted to determine the correct amount of free area ventilation requirements.

Fig. 5c Incorrectly raising the cooker

Page 11
Image 11
Fisher & Paykel OR120 Installation instructions, Moving the cooker, Ventilation requirements GB & IE only