Fluke 2635A-RF900USB instruction sheet MHz RF USB Modem, Introduction, Contacting Fluke

Models: 2635A-RF900USB

1 2
Download 2 pages 1003 b
Page 1
Image 1
Introduction

Introduction

The 2635A-RF900USB 900 MHz RF USB Modem (referred to as “the Modem”) is a radio-frequency transceiver that, used together with the 2635A-RF900 Serial RS-232 Modem, creates a wireless link between Fluke Hydra Series Data Loggers and a computer (PC) running Hydra application software.

Note

The modem operates in the 900 MHz frequency range and is approved by the FCC for use in the United States. Operation in other countries may violate local regulations. When operating outside the United States, check with the appropriate governing agency in the host country prior to Modem operation.

This instruction sheet assumes familiarity with the Hydra software and Hydra Series Data Logger operation. If unfamiliar with Hydra software or the Hydra Series hardware, refer to the software user’s documentation or the appropriate Hydra Series Users manual. The Modem is shown in Figure 1.

®

2635A-RF900USB

900 MHz RF USB Modem

Instruction Sheet

Contacting Fluke

To locate an authorized service center, visit us on the World Wide Web at www.fluke.com or call Fluke using any of the following numbers:

USA: 1-888-99-FLUKE (1-888-993-5853)

Canada: 1-800-36-FLUKE (1-800-363-5853)

Europe: +31 402-678-200

Japan: +81-3-3434-0181

Singapore: +65-738-5655

Anywhere in the world: +1-425-446-5500

Shipping Contents

The Modem comes with the following items:

Instructions for use with the Hydra Series (this sheet)

Quick Start Guide

CD-ROM with documentation and software

½ wave Dipole Antenna

USB (Universal Serial Bus) 6 ft. cable

Requirements

Antenna

Reset Config

Switch Switch

The Modem requires a PC with one free USB port and Windows XP, 2000, or 98 SE.

Installation

Data Out

USB Port

 

 

 

 

 

Connector

 

 

 

 

Data In

 

 

 

 

 

 

 

Power Indicators

 

 

 

nnetoP

 

 

 

 

 

 

a

etRr

 

 

 

 

 

 

 

nA

 

 

 

 

 

 

 

h

 

 

 

 

 

 

 

fig itc

wS

 

 

 

 

 

 

n

 

 

 

 

 

 

oC

 

 

 

 

 

 

 

h

 

 

 

 

 

 

 

t cit

 

 

 

 

 

 

es

w

 

 

 

 

 

 

eR S

On

 

 

 

 

 

 

 

Off

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D a

 

 

 

 

 

 

 

P a ta

Ou

 

 

 

 

 

 

ta

 

 

 

 

 

 

ower In t

 

 

 

 

 

 

 

PoSerial

 

 

 

 

Power Adapter Jack

 

 

rt

 

 

 

 

 

 

7-18

 

 

 

 

 

 

O-

V

 

 

 

 

 

 

O- D

 

 

 

 

 

 

O

C

 

 

 

efef01.eps

Figure 1. 2635A-RF900USB 900 MHz RF USB Modem

Each wireless system requires two modems – one base station connected to a PC, and one remote station connected to a Hydra Data Logger. This USB Modem is used as a base station connected to the PC; the remote station connected to the Hydra is a 2635A- RF900 Serial RS-232 Modem.

To ease system setup, the Modem’s factory default settings are correct for proper PC-to-Hydra operation without further adjustments. There are no setup differences between the base and remote stations.

PN 2558814 November 2005 ©2005 Fluke Corporation. All rights reserved. Printed in U.S.A.

1

Page 1
Image 1
Fluke 2635A-RF900USB instruction sheet MHz RF USB Modem, Introduction, Contacting Fluke, Shipping Contents, Requirements