Specifications continued

Accuracy, resolution and range

 

 

 

 

 

Volt/Amps/Hertz

 

 

 

Measurement range

Resolution

 

 

Accuracy

 

Vrms (AC+DC)

 

 

 

1 to 1000 Vrms

0.1 Vrms

 

 

± 0.5 % of nominal voltage

 

Vpk

 

 

 

 

1 to 1400 Vpk

1 V

 

 

5 % of nominal voltage

 

CFV

 

 

 

 

1.0 to > 2.8

0.1

± 5 %

 

Arms (AC+DC)

 

 

 

0 to 20,000 Arms1

0,001 to 10 Arms1

 

 

± 1 % of reading ± 5 counts3

 

 

with included clamps

0 to 400 Arms

0.1 and 1 Arms

 

 

 

 

Apk

using 1mV/A scaling

0 - 5500 Apk

10 A

± 5 %

 

CFA

using 1mV/A scaling

1 to 10

0.1

± 5 %

 

50 Hz nominal

 

 

 

42.50 to 57.50 Hz

0.01 Hz

 

 

± 0.1 % of nominal frequency

 

60 Hz nominal

 

 

 

51.00 to 69.00 Hz

0.01 Hz

 

 

± 0.1 % of nominal frequency

 

Dips and swells

 

 

 

 

 

 

 

 

 

 

Vrms12 (AC+DC)

 

 

 

0.0 to100 % of nominal voltage

0.1Vrms

 

 

± 1 % of nominal voltage

 

Arms12 (AC+DC)

 

 

 

0 to 20,000 Arms1

0,001 Arms to 10 Arms

 

 

± 1 % of reading ± 5 counts3

 

 

with included clamps

0 to 400 Arms

0.1 Arms and 1 Arms

 

 

 

 

Threshold levels

 

 

 

Programmable in percent of nominal

voltage

 

 

 

 

Duration

 

 

 

hhh,mm,ss,mmm with half-cycle cycle time resolution

 

 

 

 

Harmonics

 

 

 

 

 

 

 

 

 

 

Harmonic selection (n)

DC, 1 to 50

 

 

 

 

 

Inter-Harmonic selection

Off, 1 to 49

 

 

 

 

 

Vrms

Relative (%f):

0.0 to 100.0 %

0.1 %

 

 

± 0.1 % ± n x 0.1 %

 

 

 

 

 

 

 

 

 

 

 

(± 0.4 % for %r)

 

 

 

Absolute:

0.0 to 1000 Vrms

0.1 Vrms

 

 

± 5 % of reading ± 2 counts

 

Arms

Relative (%f):

0.0 to 100.0 %

0.1 %

 

 

± 0.1 % ± n x 0.1 %

 

 

 

 

 

 

 

 

 

 

 

(± 0.4 % for %r)

 

 

 

Absolute:

0.0 to 4000 mV x selected

1 mVrms x selected clamp scaling

 

 

± 5 % of reading ± 5 counts

 

 

 

 

 

 

clamp scaling

 

 

 

 

 

Watts

 

Relative:

0.0 to 100.0 %

0.1 %

 

 

± n x 2 %

 

 

 

Absolute:

depends on selected clamp

 

 

 

± 5 % of reading ± n x 2 %

 

 

 

 

 

 

and voltage scaling

 

 

 

of reading, ± 10 counts

 

DC voltage

Relative:

0.0 to 100.0 %

0.1 %

± 1 %

 

 

 

Absolute:

0.0 to 1000 V

0.1 V

 

 

± 5 % of reading ± 10 counts

 

THD

 

 

 

 

0.0 to 100.0 %

0.1 %

± 2.5 %

 

Hz

 

 

 

 

0 to 3500 Hz

1 Hz

 

 

± 1Hz

 

Phase angle

 

 

 

-360 º to +360 º

1 º

 

 

± n x 1.5 º

 

Power and Energy

 

 

 

 

 

 

 

 

Watt

 

 

 

 

1.0 W to 20.00 MW1

0.1 W to 1 kW1

 

 

± 1.5 % of reading ± 10 counts3

 

VA

 

 

 

 

1.0 VA to 20.00 MVA1

0.1 VA to 1 kVA1

 

 

± 1.5 % of reading ± 10 counts3

 

VAR

 

 

 

 

1.0 VAR to 20.00 MVAR1

0.1 VAR to 1 kVAR1

 

 

± 1.5 % of reading ± 10 counts3

 

kWh

 

 

 

 

00.00 kWhr to 200.0 GWhr1

0.01 Whr to 100 Whr1

 

 

± 1.5 % of reading ± 10 counts3

 

kVA

 

 

 

 

00.00 kVAhr to 200.0 GVAhr1

0.01 VAhr to 100 VAhr1

 

 

± 1.5 % of reading ± 10 counts3

 

kVAR

 

 

 

 

00.00 kVARhr to 200.0 GVARhr1

0.01 VARhr to 100 VARhr1

 

 

± 1.5 % of reading ± 10 counts3

 

Power Factor

 

 

 

0 to 1

0.01

± 0.033

 

Cos ϕ / DPF

 

 

 

0 to 1

0.01

± 0.033

 

Flicker

 

 

 

 

 

 

 

 

 

 

Pst (1min), Pst, Plt, PF5

0.00 to 20.00

0.01

 

 

Within ± 5 % of tabulated values

 

instantenous Flicker

 

 

 

 

 

according IEC61000-4-15

 

Dc %, Dmax % and Time d(t)

0.0 to ± 100.0 % for Dc % and

0.1 % for Dc % and Dmax % and

 

 

± 1% for Dc % and Dmax % and

 

exceeds limits. As described

Dmax % and 0.000 to 9.999s

10 ms for Time

 

 

20 ms for Time

 

per IEC 61000-3-3

for Time

 

 

 

 

 

Unbalance

 

 

 

 

 

 

 

 

 

 

Volts

 

 

 

 

0.0 to 5.0 %

0.1 %

± 0.5 %

 

Current

 

 

 

0.0 to 20 %

0.1 %

± 1 %

 

Transient capture

 

 

 

 

 

 

 

 

Volts

 

 

 

 

± 6000 Vpk

1 V

 

 

± 15 % of cursor reading

 

 

 

 

 

 

 

 

 

 

 

± 2.5 % of Vrms

 

Minimum detect duration

5 µs

Sampling rate

 

 

200 kS/s

 

Inrush mode

 

 

 

 

 

 

 

 

 

 

Arms (AC+DC)

 

 

 

0.000 to 20.00 kArms1

0.001 to 10 Arms1

 

 

± 1 % of meas ± 5 counts3

 

Inrush Duration

 

 

 

mm:ss:mmm between 7.5 s to

10 ms

 

 

± 20 ms (Fnominal = 50 Hz)

 

 

 

 

 

 

30 m selectable

 

 

 

 

 

 

 

 

 

 

 

 

Fluke 430 Series Three-Phase Power Quality Analyzers Fluke Corporation 5