Specifications continued
Accuracy, resolution and range |
|
|
|
|
| ||||||
Volt/Amps/Hertz |
|
|
| Measurement range | Resolution |
|
| Accuracy |
| ||
Vrms (AC+DC) |
|
|
| 1 to 1000 Vrms | 0.1 Vrms |
|
| ± 0.5 % of nominal voltage |
| ||
Vpk |
|
|
|
| 1 to 1400 Vpk | 1 V |
|
| 5 % of nominal voltage |
| |
CFV |
|
|
|
| 1.0 to > 2.8 | 0.1 | ± 5 % |
| |||
Arms (AC+DC) |
|
|
| 0 to 20,000 Arms1 | 0,001 to 10 Arms1 |
|
| ± 1 % of reading ± 5 counts3 |
| ||
| with included clamps | 0 to 400 Arms | 0.1 and 1 Arms |
|
|
|
| ||||
Apk | using 1mV/A scaling | 0 - 5500 Apk | 10 A | ± 5 % |
| ||||||
CFA | using 1mV/A scaling | 1 to 10 | 0.1 | ± 5 % |
| ||||||
50 Hz nominal |
|
|
| 42.50 to 57.50 Hz | 0.01 Hz |
|
| ± 0.1 % of nominal frequency |
| ||
60 Hz nominal |
|
|
| 51.00 to 69.00 Hz | 0.01 Hz |
|
| ± 0.1 % of nominal frequency |
| ||
Dips and swells |
|
|
|
|
|
|
|
|
|
| |
Vrms1⁄2 (AC+DC) |
|
|
| 0.0 to100 % of nominal voltage | 0.1Vrms |
|
| ± 1 % of nominal voltage |
| ||
Arms1⁄2 (AC+DC) |
|
|
| 0 to 20,000 Arms1 | 0,001 Arms to 10 Arms |
|
| ± 1 % of reading ± 5 counts3 |
| ||
| with included clamps | 0 to 400 Arms | 0.1 Arms and 1 Arms |
|
|
|
| ||||
Threshold levels |
|
|
| Programmable in percent of nominal | voltage |
|
|
|
| ||
Duration |
|
|
| hhh,mm,ss,mmm with |
|
|
|
| |||
Harmonics |
|
|
|
|
|
|
|
|
|
| |
Harmonic selection (n) | DC, 1 to 50 |
|
|
|
|
| |||||
Off, 1 to 49 |
|
|
|
|
| ||||||
Vrms | Relative (%f): | 0.0 to 100.0 % | 0.1 % |
|
| ± 0.1 % ± n x 0.1 % |
| ||||
|
|
|
|
|
|
|
|
|
| (± 0.4 % for %r) |
|
|
| Absolute: | 0.0 to 1000 Vrms | 0.1 Vrms |
|
| ± 5 % of reading ± 2 counts |
| |||
Arms | Relative (%f): | 0.0 to 100.0 % | 0.1 % |
|
| ± 0.1 % ± n x 0.1 % |
| ||||
|
|
|
|
|
|
|
|
|
| (± 0.4 % for %r) |
|
|
| Absolute: | 0.0 to 4000 mV x selected | 1 mVrms x selected clamp scaling |
|
| ± 5 % of reading ± 5 counts |
| |||
|
|
|
|
| clamp scaling |
|
|
|
|
| |
Watts |
| Relative: | 0.0 to 100.0 % | 0.1 % |
|
| ± n x 2 % |
| |||
|
| Absolute: | depends on selected clamp |
|
|
| ± 5 % of reading ± n x 2 % |
| |||
|
|
|
|
| and voltage scaling |
|
|
| of reading, ± 10 counts |
| |
DC voltage | Relative: | 0.0 to 100.0 % | 0.1 % | ± 1 % |
| ||||||
|
| Absolute: | 0.0 to 1000 V | 0.1 V |
|
| ± 5 % of reading ± 10 counts |
| |||
THD |
|
|
|
| 0.0 to 100.0 % | 0.1 % | ± 2.5 % |
| |||
Hz |
|
|
|
| 0 to 3500 Hz | 1 Hz |
|
| ± 1Hz |
| |
Phase angle |
|
|
| 1 º |
|
| ± n x 1.5 º |
| |||
Power and Energy |
|
|
|
|
|
|
|
| |||
Watt |
|
|
|
| 1.0 W to 20.00 MW1 | 0.1 W to 1 kW1 |
|
| ± 1.5 % of reading ± 10 counts3 |
| |
VA |
|
|
|
| 1.0 VA to 20.00 MVA1 | 0.1 VA to 1 kVA1 |
|
| ± 1.5 % of reading ± 10 counts3 |
| |
VAR |
|
|
|
| 1.0 VAR to 20.00 MVAR1 | 0.1 VAR to 1 kVAR1 |
|
| ± 1.5 % of reading ± 10 counts3 |
| |
kWh |
|
|
|
| 00.00 kWhr to 200.0 GWhr1 | 0.01 Whr to 100 Whr1 |
|
| ± 1.5 % of reading ± 10 counts3 |
| |
kVA |
|
|
|
| 00.00 kVAhr to 200.0 GVAhr1 | 0.01 VAhr to 100 VAhr1 |
|
| ± 1.5 % of reading ± 10 counts3 |
| |
kVAR |
|
|
|
| 00.00 kVARhr to 200.0 GVARhr1 | 0.01 VARhr to 100 VARhr1 |
|
| ± 1.5 % of reading ± 10 counts3 |
| |
Power Factor |
|
|
| 0 to 1 | 0.01 | ± 0.033 |
| ||||
Cos ϕ / DPF |
|
|
| 0 to 1 | 0.01 | ± 0.033 |
| ||||
Flicker |
|
|
|
|
|
|
|
|
|
| |
Pst (1min), Pst, Plt, PF5 | 0.00 to 20.00 | 0.01 |
|
| Within ± 5 % of tabulated values |
| |||||
instantenous Flicker |
|
|
|
|
| according |
| ||||
Dc %, Dmax % and Time d(t) | 0.0 to ± 100.0 % for Dc % and | 0.1 % for Dc % and Dmax % and |
|
| ± 1% for Dc % and Dmax % and |
| |||||
exceeds limits. As described | Dmax % and 0.000 to 9.999s | 10 ms for Time |
|
| 20 ms for Time |
| |||||
per IEC | for Time |
|
|
|
|
| |||||
Unbalance |
|
|
|
|
|
|
|
|
|
| |
Volts |
|
|
|
| 0.0 to 5.0 % | 0.1 % | ± 0.5 % |
| |||
Current |
|
|
| 0.0 to 20 % | 0.1 % | ± 1 % |
| ||||
Transient capture |
|
|
|
|
|
|
|
| |||
Volts |
|
|
|
| ± 6000 Vpk | 1 V |
|
| ± 15 % of cursor reading |
| |
|
|
|
|
|
|
|
|
|
| ± 2.5 % of Vrms |
|
Minimum detect duration | 5 µs | Sampling rate |
|
| 200 kS/s |
| |||||
Inrush mode |
|
|
|
|
|
|
|
|
|
| |
Arms (AC+DC) |
|
|
| 0.000 to 20.00 kArms1 | 0.001 to 10 Arms1 |
|
| ± 1 % of meas ± 5 counts3 |
| ||
Inrush Duration |
|
|
| mm:ss:mmm between 7.5 s to | 10 ms |
|
| ± 20 ms (Fnominal = 50 Hz) |
| ||
|
|
|
|
| 30 m selectable |
|
|
|
|
| |
|
|
|
|
|
|
| Fluke 430 Series |