Specifications continued
General
Case
Design | Rugged, shock proof with integrated protective holster | ||
Drip and dust proof | IP51 according to IEC60529 when used in tilt stand position | ||
Shock and Vibration | Shock 30 g, Vibration: 3 g Sinusoid, Random 0.03 g2/Hz according to | ||
Display |
|
|
|
Type | Bright | ||
Size | 115.2 x 86.4 mm (4.5 x 3.4 in) | ||
Resolution | 320 x 240 pixels | ||
Contrast and brightness | User adjustable, temperature compensated | ||
Memory |
|
| |
Screens | 50 screen memories on Fluke 434 | ||
|
|
| 25 screen memories on Fluke 433 |
Data | 10 data memories for storing data including recordings on Fluke 434 | ||
|
|
| 5 data memories for storing data including recordings on Fluke 433 |
Limit templates | 2 preprogrammed, 2 administrator (programmable via FlukeView, 2 user locations) | ||
Time and date stamp for AutoTrend, Transient display and SystemMonitor | |||
Mechanical |
| ||
Size | 256 x 169 x 64 mm (10 x 6.6 x 2.5 in.) | ||
Weight | 2 kg (4.4 lb.) | ||
Power |
| ||
Line power | Switchable 115 V, 230 V adapter with country specific plug | ||
Battery power | Rechargeable NiMH (installed) | ||
Battery operating time | > 7 hours | ||
Battery charging time | 4 hours | ||
Power saving | Adjustable time for dimmed backlight with on screen power indicator | ||
Standards |
| ||
Measurement methods used | |||
Power Quality | EN50160 | ||
Flicker | IEC | ||
Harmonics | IEC | ||
Safety |
| ||
Compliance | |||
Max voltage on banana input | CAT III 1000 V / CAT IV 600 V | ||
Max voltage on current BNC input | 42 Vpeak | ||
Environmental |
| ||
Operating temperature | 0 °C to +50 °C (32 °F to 122 °F) | ||
Storage temperature | |||
Humidity | 10 to 30 °C: 95 % RH non condensing (50 to 86 °F: 95 % RH non condensing) | ||
|
|
| 30 to 40 °C: 75 % RH non condensing (86 to 104 °F: 75 % RH non condensing) |
|
|
| 40 to 50 °C: 45 % RH non condensing (104 to 122 °F: 45 % RH non condensing) |
Maximum operating altitude | 3000 m (9842 ft) Derate to CAT II 1000 V / CAT III 600 V / CAT IV 300 V above 2000 m (6561 ft) | ||
Maximum storage altitude | 12 km (39,372 ft) | ||
Warranty | 3 years on mainframe, 1 year on included accessories | ||
Accessories |
| ||
Included | Hard carrying case with clamp holders BC430 | ||
|
|
| 4 current clamps, i400s |
|
|
| 5 Test leads, 4 black, 1 green |
|
|
| 5 Alligator clips, 4 black, 1 green |
|
|
| Battery Charger Eliminator, BC430 |
|
|
| FlukeView Software, SW43W (Fluke 434 only) |
|
|
| Optical Cable for USB , OC4USB (Fluke 434 only) |
|
|
| Color localization set, WC100 |
|
|
| Getting Started (printed) |
|
|
| User Manual |
1depending clamp scaling
250 Hz/60 Hz nominal frequency according to IEC
3Add clamp accuracy
4The advanced functions: interharmonics, energy, transients and inrush are optional for the Fluke 433 and standard available on the Fluke 434
Fluke 430 Series