Fluke 51 Series user manual Replacement Parts and Accessories, Electrical cont, 51 & 52 Series

Models: 51 Series 52 Series

1 20
Download 20 pages 26.54 Kb
Page 19
Image 19
Electrical (cont.)

51 & 52 Series II

Replacement Parts and Accessories

Electrical (cont.)

Replacement Parts and Accessories

Measurement Accuracy, T1, T2, or T1-T2 (Model 52)

Temperature Coefficient

Electromagnetic Compatibility

Maximum

Differential

Common Mode

Voltage

Temperature Scale

Applicable

Standards

J-, K-, T-, and E-type: ±[0.05 % of reading + 0.3 oC (0.5 oF)]

[below 100 oC (148 oF): add 0.15 % of reading for J-, K-, E-, and N-type; and 0.45 % of reading for T-type]

0.01 % of reading + 0.03 oC per oC (0.05 oF per oF) outside the specified +18 oC to 28 oC (+64 oF to +82 oF) range

[below 100 oC (148 oF): add

0.04% of reading for J-, K-, E-, and N-type; and 0.08 % of reading for T-type]

Susceptibility: ±2 oC (±3.6 oF) for 80 MHz to 200 MHz in 1.5 V/m field, for 200 MHz to 1000 MHz in 3 V/m field.

Emmisions: Commercial Limits per EN50081-1

1 V (Maximum voltage difference between T1 and T2)

ITS-90

NIST-175

Accessory

Holster and Flex StandAssembly

AANEDA 15A IEC LR6 batteries 80PK-1 K-Type Bead Thermocouple

CD-ROM Service Manual

Part Number

1272438

376756

773135

1276106

1276123

Accuracy is specified for ambient temperatures between 18 oC (64 oF) and 28 oC (82 oF) for a period of 1 year. The above specifications do not include thermocouple error.