Fluke 566, 568 user manual Specifications

Models: 568 566

1 30
Download 30 pages 12.45 Kb
Page 28
Image 28

566/568 Users Manual

Specifications

Feature

 

 

566

 

 

 

 

 

568

 

 

 

 

 

IR Temperature Range

-40 °C to 650 °C

 

 

-40 °C to 800 °C

(-40 °F to 1200 °F)

 

 

(-40 °F to 1470 °F)

 

 

 

 

<0 °C: ±(1.0 °C + 0.1 °/1 °C)

 

 

 

 

 

Accuracy

>0 °C: ±1 % or ± 1.0 °C, whichever is greater

 

 

 

(<32

F±2 °F ±0.1 °/1 °F)

 

 

 

 

 

 

 

 

 

 

 

 

>32 °F: ±1 % or ±2 °F), whichever is greater

 

 

 

Repeatability

±0.5 % of reading or ±0.5 °C (1 °F), whichever is greater.

 

 

 

 

 

 

 

 

 

 

 

Display Resolution

0.1 °C / 0.1 °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spectral Response

8 to 14 μm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response Time (95%)

<500 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K-Type Thermocouple Input

-270 °C to 1372 °C (-454 °F to 2501 °F)

 

 

 

Temperature Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-270 °C to -40 °C: ±(1 °C + 0.2 °/1 °C)

 

 

 

 

K-Type Thermocouple Input

(-454 °F to -40 °F: ±(2 °F + 0.2 °/1 °F))

°

 

±

Accuracy

-40

°

C to 1372

°

C:

±

 

°

F to 2501

F:

 

 

 

1 % or 1 °C (-40

 

 

1 % or 2 °F),

 

whichever is greater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K-Type Thermocouple

0.1 °C/0.1 °F

 

 

 

 

 

 

 

 

 

Resolution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Distance:Spot

30:1

 

 

 

 

 

50:1

 

 

 

(90% energy)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Laser sighting

single laser, output <1 mW Class II, wavelength

 

 

 

630 to 670 nm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum spot size

19 mm

 

 

 

 

 

 

 

 

 

 

 

Emissivity

Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of

common materials

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data storage

20 points

 

 

 

 

99 points

 

 

 

 

 

 

 

 

 

 

 

 

 

Communication

none

 

 

 

 

USB 2.0

 

 

 

 

 

 

 

 

 

 

 

Operating Altitude

3000 meters above mean sea level

 

 

 

 

 

 

 

 

 

 

 

 

Storage Altitude

12,000 meters above mean sea level

 

 

 

 

 

 

 

Relative Humidity

10 % to 90 % RH non-condensing up to 30 °C (86 °F)

 

 

 

 

 

 

 

Operating Temperature

0 °C to 50 °C (32 °F to 122 °F)

 

 

 

 

 

 

 

 

 

 

 

 

Storage Temperature

-20 °C to 60 °C (-4 °F to 140 °F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vibration

2.5 G, IEC 68-2-6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

0.322 kg (0.7099 lb)

 

 

 

 

 

 

 

Dimensions

17.69 cm (6.965 in) H x 16.36 cm (6.441 in) L x 5.18 cm (2.039 in) W

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

2 AA /LR6 Batteries

2 AA /LR6 Batteries

 

or USB connection when used

 

 

 

 

 

 

 

 

with a PC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

Page 28
Image 28
Fluke 566, 568 user manual Specifications