POTENTIAL LETHAL VOLTAGE

Ensure that the power supply is off and disconnected from the input power and never operate the power supply without a load cap. Make sure that all load capacitors are discharged and shorted to ground before making any connections. Lambda EMI recommends the use of safety dump switches in high voltage discharge circuits.

Never handle the HV cable during operation.

This power supply is designed to operate with a capacitive load. Operation of the power supply without an external load capacitor may result in damage to internal circuitry.

Always use the HV connector and cable provided with the power supply or an equivalent substitute provided by EMI. Fully insert the connector end of the HV cable and tighten the locking nut only "hand tight".

NOTE: When operating above 20 kV and 200 Hz rep. rate, ensure that a silicone grease (such as Dow Corning DC-4) is applied to the HV cable before insertion into the HV connector. This displaces the air in the connector and reduces long term corona effects.

Keep the minimum HV cable bend radius greater than 4 inches (101.6mm) to minimize stress on the insulation. Keep the HV cable as distant as possible from the input power and the input control signals.

Some peak current will flow out of the power supply during discharge and return through

the HV return and system chassis. This current comes from voltage reversal in underdamped systems and from normal discharge of filter and cable capacitance. The path for this current should not parallel control signal returns since the resulting voltages could interfere with normal system operation. The currents developed with voltage reversal at high rep. rates, could damage the power supply. A resistor in series with the HV output can be added to limit this current to an acceptable level. Refer to Section 5.2, Page 15 for more information.

The oil-filled HV assembly should not be opened. The oil and components have been specially cleaned and vacuum impregnated at the factory and the assembly hermetically sealed. Opening the assembly will compromise performance and void the warranty. Tanks must only be serviced at Lambda EMI.

    

83-493-001 Revision G

3 - 3

Installation

Page 15
Image 15
Fluke pmn instruction manual     ,

pmn specifications

Fluke PMN, or Fluke Precision Measurement Network, is an advanced solution designed to enhance the reliability and accuracy of metrology in various applications. This system is aimed at professionals in industries such as manufacturing, aerospace, telecommunications, and utilities, where precision measurement is critical.

One of the main features of Fluke PMN is its integrated measurement capabilities. The system combines multiple measurement functions, including voltage, current, resistance, frequency, and temperature, enabling users to perform comprehensive assessments without the need for multiple devices. This integration simplifies workflows and reduces the time spent on measurements.

Fluke PMN utilizes cutting-edge measurement technologies to ensure high accuracy and repeatability. One notable technology is its advanced digital signal processing, which minimizes noise and enhances the clarity of measurements. This results in significantly improved measurement precision, especially in complex environments where interference is prevalent.

Another key characteristic of Fluke PMN is its scalability. The system can be expanded with additional modules to adapt to the specific needs of a business. This modularity makes it a versatile choice for organizations looking to grow their measurement capabilities over time without the need for complete system overhauls.

Fluke PMN also supports remote monitoring and management through cloud technology. Users can access real-time data, generate reports, and perform analysis from virtually anywhere, making it easier to manage multiple measurement sites and maintain consistent quality standards across operations.

The user-friendly interface is another significant aspect of Fluke PMN. The intuitive design allows users to easily navigate through its various functions, ensuring that even personnel with minimal training can operate the system efficiently. This aspect greatly reduces the learning curve and improves overall productivity.

In addition to these features, Fluke PMN is built to withstand the rigors of industrial environments. Its durable construction ensures longevity and reliability, minimizing downtime due to equipment failure. This resilience is crucial for industries that depend on continuous operation and stringent adherence to quality control standards.

Overall, Fluke PMN represents a powerful solution for precision measurement. With its integrated capabilities, advanced technologies, scalability, remote monitoring, and robust design, it equips professionals with the tools they need to enhance accuracy, streamline operations, and uphold the highest standards of quality in their respective fields.