Flymo 2500 manual Cables

Models: 2500

1 8
Download 8 pages 9.72 Kb
Page 3
Image 3
CABLES

3.Do not use the product if the electric cables are dam- aged or worn.

4.Immediately disconnect from the mains electricity supply if the cable is cut, or the insulation is damaged. Do not touch the electric cable until the electrical supply has been discon- nected. Do not repair a cut or damaged cable. Replace it with a new one.

5.Your electric cable must be uncoiled, coiled cables can overheat and reduce the efficiency of the product.

6.Do not pull cable around sharp objects.

7.Always switch off at the mains before disconnecting any plug, cable connector or extension cable.

8.Switch off, remove plug from mains and examine electric supply cable for damage or ageing before winding cable for storage. Do not repair a damaged cable, replace it with a new one. Use only genuine re- placement cable.

9.Never carry the product by the cable.

10.Never pull on the cable to disconnect any of the plugs 11.Always wind cable carefully, avoiding kinking. 12.Use only on AC mains supply voltage shown on the

product rating label.

13.Our products are double insulated to EN60335. Under no circumstance should an earth be connected to any part of the product.

Preparation

1.While using your product always wear substantial footwear and long trousers.

2.The use of eye protection is recommended.

3.The use of ear protection is recommended.

4.To prevent dust irritation, the wearing of a face mask is recommended.

5.Do not wear loose clothing or jewellery that can be drawn into the air inlet.

6.Do not wear clothing with attachments, i.e. toggles or drawstrings that can be drawn into the air inlet.

7.Inspect your product before each use.

8.Do not use if any part is damaged or broken or if any of the screws are loose. Have it repaired by an autho- rised repairer.

9.Always check your product is in a safe operating con-

dition before use.

Use

1.Use the product only in daylight or good artificial light.

2.Do not use the product when it is raining or in damp and wet areas.

3.Never use the product in or near water or ponds.

4.Know how to stop the product quickly in an emergency.

5.On slopes, be extra careful of your footing and wear non-slip footwear.

6.Do not walk backwards whilst operating your product, you could trip. Walk, never run.

7.Always direct the cable to the rear, away from the product.

8.Keep children, pets and bystanders at a safe distance when using your product.

9.Keep long hair away from air inlet.

10.Keep all inlets clear of debris. 11.Always remain alert.

12.Do not attempt to use your product without the fully assembled debris bag fitted.

13.Never blow debris in the direction of bystanders. 14.Do not overreach. Keep proper footing and balance

at all times.

15.The impeller continues to rotate after your product has been switched off.

16.Remove the plug from the mains :-

-before removing or replacing fully assembled debris bag;

-before leaving the product unattended for any period;

-before clearing a blockage;

-before checking, cleaning or working on the product;

-if the product starts to vibrate abnormally. Check im- mediately. Excessive vibration can cause injury.

Maintenance and storage

1.Keep all nuts, bolts and screws tight to be sure the product is in a safe working condition.

2.Replace worn or damaged parts for safety.

3.Use only genuine replacement parts and accessories

4.Inspect the debris bag regularly. If the debris bag be- comes worn or damaged, replace.

5.Store in a cool dry place and out of reach of children. Do not store outdoors.

CABLES

1. No earth required. Flymo products are double in-

IMPORTANT

 

sulated to EN60335 and under no circumstances

Use only 1.00mm2 size cable up to 40 metres

 

should an earth be connected to any part of the

 

length maximum.

 

product.

 

 

 

Maximum rating :

2. Ensure the mains voltage suits your product

1.00mm2 size cable, 10 amps 250 volts AC.

3. IMPORTANT!

 

 

YOUR PRODUCT IS SUPPLIED WITH CABLE

 

The wires in the mains lead are coloured in accor-

1.

WIRED DIRECTLY INTO THE PRODUCT.

 

dance with the following code:

Flymo Mains Cables and Extension Cables are

 

BLUE

-

NEUTRAL

2.

available from your local Approved Service Centre.

 

BROWN

-

LIVE

Do not wire an extension cable directly to your

 

The wire which is coloured BLUE must be con-

 

product yourself. Please contact your local Ap-

 

nected to the Terminal which is marked with the

 

proved Service Centre for further information on the

 

letter 'N' or coloured BLACK.

3.

connectors and kits available.

 

The wire which is coloured BROWN must be con-

Only use extension cables specifically designed

 

nected to the Terminal which is marked with the

 

for outdoor use.

 

letter 'L' or coloured RED.

CONNECTORS

4. It is important that the outer sheath is clamped

IMPORTANT

 

correctly into the 3-pin plug.

Flymo connectors are suitable for use with 2 core

5. If in doubt consult your local Service Repairer or

 

cable only. Under no circumstances should these

 

qualified electrician before the machine is used.

connectors be used for earthed products.

6. A 13 Amp fuse must be fitted to the Mains Plug.

All Flymo connectors and cables are of splashproof

7. The normal plug fuse and household fuse only

 

construction. They are not waterproof and must not be

 

protect the electrical equipment and are not a

 

left outside permanently nor should they be sub-

 

safeguard against electrocution.

 

merged or immersed in water. Do not let cable lay or

 

 

 

 

 

 

trail through pools of water or splashed with water from

 

 

 

 

 

 

hose pipes.

 

 

 

 

 

MAINS PLUG REPLACEMENT

 

If the mains cable is damaged, it must be replaced

 

IMPORTANT

 

 

 

with the correct Flymo assembly from an Flymo Ap-

 

If the plug supplied is cut off it should be destroyed.

 

 

 

proved Service Dealer (see leaflet enclosed in prod-

 

 

There is an electric shock hazard if a cut off plug is

 

 

 

 

uct)

 

 

 

 

inserted into a 13 amp socket.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 