Flymo EASICUT 500, 420 manual Cables, Assembly

Models: EASICUT 500 420

1 9
Download 9 pages 2.51 Kb
Page 5
Image 5
Cables

Cables

CABLES

IMPORTANT

Use only 1.00mm2 size cable up to 40 metres length

maximum.

Maximum rating :

1.00mm2 size cable, 10 amps 250 volts AC.

YOUR HEDGETRIMMER IS SUPPLIED WITH CABLE WIRED DIRECTLY INTO THE PRODUCT.

1.Mains Cables and Extension Cables are available from your local Approved Service Centre.

2.Do not wire an extension cable directly to your prod- uct yourself. Please contact your local Approved Service Centre for further information on the connec- tors and kits available.

3.Only use extension cables specifically designed for

outdoor use.

CONNECTORS

IMPORTANT

Connectors are suitable for use with 2 core cable only. Under no circumstances should these connec- tors be used for earthed products.

All connectors and cables are of splashproof con- struction. They are not waterproof and must not be left outside permanently nor should they be sub- merged or immersed in water. Do not let cable lay or trail through pools of water or splashed with water

from hose pipes.

MAINS PLUG REPLACEMENT

IMPORTANT

If the plug supplied is cut off it should be de- stroyed. There is an electric shock hazard if a cut off plug is inserted into a 13 amp socket.

1.No earth required. Our products are double insu- lated to EN60745 and under no circumstances should an earth be connected to any part of the prod- uct.

2.Ensure the mains voltage suits your product

3.IMPORTANT!

The wires in the mains lead are coloured in accor- dance with the following code:

BLUE - NEUTRAL BROWN - LIVE

The wire which is coloured BLUE must be connected to the Terminal which is marked with the letter 'N' or coloured BLACK.

The wire which is coloured BROWN must be con- nected to the Terminal which is marked with the letter 'L' or coloured RED.

4.It is important that the outer sheath is clamped cor- rectly into the 3-pin plug.

5.If in doubt consult your local Service Repairer or qualified electrician before the machine is used.

6.A 13 Amp fuse must be fitted to the Mains Plug.

7.The normal plug fuse and household fuse only pro- tect the electrical equipment and are not a safeguard against electrocution.

If your product is hard wired i.e. non-detachable mains electric cable, a conversion kit and exten- sion cable is available from all Approved Service Centres which can be found in your local Yellow Pages.