Flymo Trimmer I instruction manual Safety, Cables, F Brown, Black, Blue

Models: Trimmer I

1 15
Download 15 pages 61.71 Kb
Page 5
Image 5
CABLES

4

SAFETY

CABLES

IMPORTANT

Use only 1.00mm2 size cable up to 30 metres length maximum for trimmers and 60 metres length maximum for lawnmowers.

Maximum rating:

1.00mm2 size cable, 10 amps 250 volts AC.

1.Flymo products are supplied with either an electric mains cable fitted with a female connector or with an electric mains cable wired directly into the product.

THE MINI-TRIM IS SUPPLIED WITH AN ELECTRIC MAINS CABLE WIRED DIRECTLY INTO THE PRODUCT.

2.Flymo Mains Cables and Extension Cables are available from your local Flymo/Partner Approved Service Centre.

3.Do not wire an extension cable directly to your product yourself. Please contact your local Flymo/Partner Approved Service Centre for further information on the connectors and kits available.

4.Only use extension cables specifically designed for outdoor use.

CONNECTORS

IMPORTANT

Flymo connectors are suitable for use with 2 core cable only. Under no circumstances should these connectors be used for earthed products.

All Flymo connectors and cables are of splashproof construction. They are not waterproof and must not be left outside permanently nor should they be submerged or immersed in water. Do not let cable lay or trail through pools of water or splashed with water from hose pipes.

MAINS PLUG REPLACEMENT

IMPORTANT

If the plug supplied is cut off it should be destroyed. There is an electric shock hazard if a cut off plug is inserted into a 13 amp socket.

1.No earth required. Flymo products are double insulated to BS3456 and under no circumstances should an earth be connected to any part of the product.

2.Ensure the mains voltage suits your product.

3.IMPORTANT!

 

E

 

 

L

RED

 

 

OR

 

 

F BROWN

BLACK

 

U

 

S

OR

N

E

BLUE

 

 

 

 

The wires in the mains lead are coloured in accordance with the following code:

BLUE - NEUTRAL

BROWN - LIVE

The wire which is coloured BLUE must be connected to the Terminal which is marked with the letter ‘N’ or coloured BLACK. The wire which is coloured BROWN must be connected to the Terminal which is marked with the letter ‘L’ or coloured RED.

4.It is important that the outer sheath is clamped correctly into the 3-pin plug.

5.If in doubt consult your local Service Repairer or qualified electrician before the machine is used.

6.A 5 Amp fuse must be fitted to the Mains Plug.

7.The normal plug fuse and household fuse only protect the electrical equipment and are not a safeguard against electrocution.

For Further information on Mains Cables, Extension Cables, Cable Connectors and kits contact Flymo/Partner Customer Service direct:-

Telephone

:

01325 300303

Fax

:

01325 318193

Page 5
Image 5
Flymo Trimmer I instruction manual Safety, Cables, F Brown, Black, Blue