REPLACEMENT LOG SET
INSTALLATION INSTRUCTIONS
FOR BTB18, BTB24, PDG18 AND PDG24 GAS LOG HEATERS
WARNING: If log set has been in use, make sure control knob is in the OFF position, unit is cold and gas has been turned off.
3.Place new log set assembly over chassis and align holes on bracket with holes on chassis (see Figure 2).
4.Replace six screws removed in step 1.
Part No. | Description | Qty. |
Replacement Log Set 18'' - BTB18 | 1 | |
Replacement Log Set 18'' - PDG18 | 1 | |
Replacement Log Set 24'' - BTB24 | 1 | |
Replacement Log Set 24'' - PDG24 | 1 | |
Flex Tube | 1 | |
Compression Nut/Sleeve | 2 |
Your replacement kit will contain only one log set assembly depending on your model. If there is a problem with your replacement log set contact the authorized dealer where you bought the set or FMI PRODUCTS, LLC at
Items Needed for Installation:
•5/16'' Hex Socket Wrench or Nut Driver
•Phillips Screwdriver
•5/8'' Wrench or Adjustable Wrench
1.Remove six screws from sides of log set assembly (three on each side). Remove log set assembly (see Figure 1). Do not pull on log assembly to remove. Work log set off chassis by manipulating metal base.
2.18'' models only: Disconnect flexible gas line from valve and burner (see Figure 1). Discard flex line.
24" Set | Disconnect | 18" Set | |
Flexible Gas Line | |||
|
| ||
| Figure 1 - Removing Log Set |
|
Bracket
24" Set
Chassis
Bracket
18" Set | Chassis |
|
Figure 2 - Installing Replacement Log Set
Save these instructions for future reference