www.fmiproducts.com
122280-01E 31
OPERatIOnFOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
lowtheseinstructions exactly,
are or explosion may result
causingpropertydamage,per-
sonalinjuryorlossoflife.
A. Thisapplianceisequippedwithanigni-
tiondevicewhichautomaticallylights
pilot.Donottrytolightpilotbyhand.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smellnexttotheoorbecause some
gasisheavierthan airandwillsettle
ontheoor.
WHAT TO DO IF YOU SMELL GAS
•Donottrytolightanyappliance.
•Donottouchanyelectricswitch;do
notuseanyphoneinyourbuilding.
•Immediatelycall your gas supplier
fromaneighbor’sphone.Followthe
gassupplier’sinstructions.
•Ifyoucannotreachyourgassupplier,
calltheredepartment.
C. Do not use this appliance if any part
hasbeenunder water. Immediately
callaqua lied service technician to
inspect the appliance and to replace
anypartof the control system and
anygascontrolwhichhasbeenunder
water.
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation
of���newheater,burninglogswill
giveoffapaper-burningsmell.
Orangeamewillalsobepres-
ent.Openwindowtoventsmell.
Thiswillonlylastafewhours.
1. STOP! Read the safety information
above.
2. Turn off all electric power to appliance.
3. Turn wall switch to the OFF position or
press OFF on hand-held remote.
4. Fully open glass doors if installed.
5. Remove front refractory brick access
panel.
6. Turn equipment shutoff valve clockwise
to the OFF position (see Figure
39). Do not force.
7. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the
oor. If you smell gas, STOP! Follow “B”
in the safety information, column 1. If you
don’t smell gas, go to the next step.
8. Turn equipment shutoff valve counter-
clockwise to the ON position. Do
not force.
9. Replace front refractory brick access
panel.
10. Fully close glass doors if installed.
11. Turn on all electric power to appliance.
12. Turn wall switch to the ON posit ion or
press ON on hand-held remote.
13. Visually locate pilot. The ignitor should
begin to spark and main burner should
ignite once ame appears at pilot.
• If lighting appliance for the rst time each
season, it may take several attempts
before the supply gas can reach the pilot
and main burners.
• If the applian ce will not stay lit af ter
several attempts, follow the instructions
To Turn Off Gas To Appliance, page 32
and call your service technician or gas
supplier.
IN
PILOT
IN
OUT
VENT
TH
TP
TH
TP
Figure 39 - Turning Equipment Shutoff Valve to the OFF Position
Equipment
Shutoff Valve