www.fmiproducts.com 122280-01E32
OPERatIOnContinued
COMBUSTION AIR KIT
MODEL AK4 (OPTIONAL)
The outside air kit lever is located at the left
and right hand sides of replace (see Figure
40). The vent can be installed through any
outside wall a minimum of three feet below
replace termination cap. Lifting lever up will
free the outside air door to open. Pulling lever
down will lock the door.
CAUTION: Air inlet ducts are
nottoterminateinatticspace.
Open Position
Closed Position
Figure 40 - Outside Air Kit Lever
TO TURN OFF GAS
TO APPLIANCE
1. Turn off wall switch or press OFF on hand-
held remote.
2. Turn off all electric power to appliance if
service is to be performed.
3. Fully open glass doors if installed.
4. Remove front hearth brick and control
access panel.
5. Turn gas control knob clockwise
to OFF. Do not force.
6. Replace front refractory brick access
panel.
7. Fully close glass doors if installed.