FMI FVF18P, FVF24P, FVF30P Product Features, Product Identification, Local Codes, Unpacking

Models: FVF24P FVF18P FVF30P

1 24
Download 24 pages 40.08 Kb
Page 3
Image 3

OWNER’S MANUAL

SAFETY

INFORMATION

Continued

12.This heater needs fresh, outside air ven- tilation to run properly. This heater has an oxygen depletion sensor (ODS) pi- lot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Trouble- shooting, pages 17 through 19.

13.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

14.Do not use this heater to cook food or burn paper or other objects.

15.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the room heater and to replace any part of the control system and any gas control which has been under water.

16.Do not operate heater if any log is bro- ken. Do not operate heater if a log is chipped (dime-sized or larger).

17.Turn heater off and let cool before ser- vicing. Only a qualified service person should service and repair heater.

18.Operating heater above elevations of 4,500 feet could cause pilot outage.

19.Provide adequate clearances around air openings.

PRODUCT

FEATURES

OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation with flue damper closed. It has been tested and ap- proved to ANSI Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. This heater may also be operated as a vented decorative (ANSI Z21.60) product by opening the flue damper.

SAFETY PILOT

PRODUCT IDENTIFICATION

One-Piece

Log Set

Burner

Piezo Ignitor

Base Assembly

Control Knob

Figure 1 - Heat Majic™ Log Set

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

UNPACKING

CAUTION: Do not remove the data plates from the grate assem- bly. The data plates contain impor- tant product information.

1.Remove logs and heater base assem- bly from carton. Note: Do not pick up heater base assembly by the burner. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging ap- plied to logs and heater for shipment.

3.Check all items for any shipping dam- age. If damaged, promptly inform dealer where you bought heater.

105192

3

Page 3
Image 3
FMI FVF18P, FVF24P, FVF30P installation manual Product Features, Product Identification, Local Codes, Unpacking