UNVENTED PROPANE/LP GAS LOG HEATER

INSTALLATION

Continued

NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8 inches up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even

if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7 on page 9 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Operation, page 10.

Minimum Noncombustible Material Clearances

If Not Using Mantel

Note: If using a mantel, proceed to If Using a Mantel. If not using a mantel, follow the information below.

You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible mate- rial must extend at least 8" up (for all mod- els). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See Figure 5 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Noncombustible

 

Requirements for

Material Distance (A)

 

Safe Installation

 

 

 

12" or more

 

Noncombustible material OK.

Between 8" and 12"

 

24" or 30" Models: Install fireplace hood accessory

 

 

 

 

 

(GA6050, GA6052, or GA6053, see Accessories,

 

 

 

 

 

page 21).

 

 

 

 

 

18" Model: Noncombustible material OK.

Less than 8"

 

Noncombustible material must be extended to at

 

 

 

 

 

least 8". See Between 8" and 12", above. If you

 

 

 

 

 

cannot extend material, you must operate heater

 

 

 

 

 

with flue damper open.

 

 

 

 

 

 

 

Heat Resistant

 

 

 

 

 

 

 

 

 

 

 

 

Material

 

 

 

 

 

 

 

 

 

(A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

8

105192

Page 8
Image 8
FMI FVF30P, FVF18P, FVF24P Minimum Noncombustible Material Clearances, If Using Mantel, If Not Using Mantel

FVF24P, FVF18P, FVF30P specifications

The FMI FVF series of fireplaces, which includes models FVF30P, FVF18P, and FVF24P, represents a blend of contemporary design and advanced heating technology. Each model is designed to provide efficient and aesthetic warmth to any space, making them ideal for modern homes and commercial settings.

The FVF30P is the largest in the series, featuring a striking glass front that allows for an unobstructed view of the flames. Its generous heating capability makes it suitable for larger rooms, ensuring that warmth permeates every corner. Equipped with a powerful blower system, this model enhances heat distribution, making it an ideal choice for those seeking both efficiency and aesthetics.

The FVF18P, in contrast, is designed for smaller spaces, combining compact dimensions with impressive heating performance. Its sleek design allows it to fit seamlessly into any decor, while still providing the ambiance of a traditional fireplace. With advanced technology that ensures optimal combustion, this model minimizes emissions and maximizes efficiency, meeting stringent environmental standards.

The FVF24P stands as a middle ground between the two, offering versatile installation options and a balanced heating output. This model also boasts an elegant glass front that enhances visual appeal. Like its counterparts, the FVF24P incorporates modern technologies that ensure a clean burn, significantly reducing fuel consumption while maximizing output.

All models include advanced ignition systems, such as electronic ignition, making startup simple and convenient. Each unit is designed with ease of maintenance in mind, featuring removable panels and accessible components that simplify cleaning. Moreover, these fireplaces offer various finishes and trim options, allowing customization to match individual tastes and home designs.

Safety is another hallmark of the FMI FVF series. Each fireplace is equipped with safety features such as a tempered glass front, automatic shut-off systems, and optional heat management systems to prevent overheating. Customer satisfaction is further ensured through generous warranties and exceptional after-sale support provided by FMI.

In conclusion, the FMI FVF30P, FVF18P, and FVF24P models stand out in the market due to their combination of aesthetic appeal, cutting-edge technology, and commitment to efficiency and safety, making them an excellent investment for anyone looking to enhance their living space with modern warmth.