Wall

CLEARANCES

Minimum clearances to combustibles for the
replace are as follows:
*Back and sides 1"
Perpendicular walls 6"
Floor 0"
Ceiling to louver opening 42"
Front 36"
Top of Standoffs 0"
Vent (See venting instructions
for specic venting
clearances.)
Combustible material with a maximum thick-
ness of 5/8" may be ush with the top front
of replace.
* For back and sides of replace, do not pack
with insulation or other materials. 1" clearance
not required at nailing anges.

NOTICE: This replace is intend-

ed for use as supplemental heat.

Use this replace along with

your primary heating system.

Do not install this replace as

your primary heat source. If you

have a central heating system,

you may run system’s circulat-

ing blower while using replace.

This will help circulate the heat

throughout the house.

FRAMING AND FINISHING

Figure 4 shows typical framing of this replace.
Figure 5 shows framing for corner installation.
All minimum clearances must be met.
If you are using a separate combustible man-
tel piece, refer to Figure 6 for proper instal-
lation height. You can install noncombustible
mantels at any height above the replace.
Note: Noncombustible mantels may discolor!
Pre-inStALLAtiOn
Continued
43
1
/
4
"
(36")
47
1
/
4
"
(42")
41
1
/
2
"
(36")
48
1
/
2
"
(42")
Figure 4 - Framing Clearances with
Outside Air Flex Duct
Figure 5 - Framing Clearances for Corner
Installation
Figure 6 - Clearances for Combustible
Mantels
Ref.
Mantel
Depth Ref.
Mantel from
Top of Opening
114" A 16"
212" B 14"
310" C 12"
48" D 10"
56" E 8"
64" F 6"
72" G 4"
36
3
/
8
"
(36")
43
3
/
8
" (42")
43" (36"), 50" (42")
42" (36"), 49" (42")
15
3
/
4
"
(36")
19" (42")
51
3
/
8
"
(36")
61
3
/
4
" (42")
Nailing
Tabs