Fireplace Installation

Continued

64" Min.

65" Min.

 

 

 

20" Min.

16"

 

Min.

 

 

Figure 9 - Hearth Extensions

 

 

Noncombustible

 

 

Hearth

 

 

Extension

 

 

8" Max.

1

1/2" Typ.

“Z” Type Ember

Protector

 

 

 

 

Noncombustible

 

 

Hearth Extension

 

 

K” Factor

 

 

.84

1 1/2" Typ.

 

 

 

Ember Protector

Figure 10 - Raised Hearth Extension

Mantel Clearances

Woodwork such as wood trims, mantels or any other combustible material projecting from the front face must not be placed within 9" of fireplace opening.

Combustible materials above and projecting more than 1 1/2" from the fireplace front face (see Figure 11) must not be placed less than 12" from effective opening of the fireplace (NFPA STD 211, Sec. 7-3.3.3).

Mantels or any other combustible material may also come up to the side edge of the black metal face of the fireplace only if the projection from the front face falls within limits shown in Figure 12.

2" X 4" Stud

Drywall

Combustible

Materials

33°

6" Nom.

12" Min.

 

9" Min.

Fireplace Side View

 

 

Front

 

3" Nom.

Face

 

 

 

Fireplace Front View

 

1 1/2" Max.

 

 

Figure 11 - Mantel Clearances to

Combustible Materials

Top View of Fireplace

 

Seal Gaps with

 

Noncombustible

Drywall

 

 

Mortar or Adhesive

 

 

2 3/4" Max.

4"

 

 

(Approx.) 33°

 

 

Nom.

 

 

4

3/8"

Combustible

Material Must

Min.

Not Overlap

6" Nom.

 

 

Black Metal

 

 

Front Face

Figure 12 - Mantel Clearances to Metal

Face

Venting Installation

Optional Outside air Kit

The installation of an outside air kit should be performed during the rough framing of the fireplace due to the nature of it’s location. Outside combustion air is accessed through and exterior wall or a vented crawl space.

CAUTION: Air inlet ducts must not terminate in attic space.

The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination.

For further details on installation of outside air kit, please refer to instructions included with air kit.