Venting Installation

Optional Outside air Kit (Model ak4/ak4f)

The installation of an outside air kit should be performed during the rough framing of the fireplace due to the nature of it's location. Outside combustion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4). See Figure 22 on page 13 for instruction of operating air kit.

CAUTION: Combustion air inlet ducts shall not terminate in attic space.

The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination.

Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size)

Air Inlet

Location

Must Allow For Bushes or Snow

 

Air Inlet

 

Eyebrow

Vented Crawl Space

Vent Hood

Required for

(Check Local Codes

Wall Installation

Before Installing in a

 

Vented Crawl Space)

 

Figure 5 - Outside Air Kit

Chimney Pipe

The FMI PRODUCTS, LLC chimney system

consists of 12", 18", 24", 36" and 48" snap- lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fitting overlaps must be taken into consideration

(lineal gain) and are given in the lineal gain

chart (see Figure 6). Lineal gain is the actual measurable length of a part after two or more parts are connected. For Canada, use chimney

parts designated "HT".

WARNING: The opening in collar around chimney at top of fireplace must not be obstruct- ed. Never use blown insulation to fill chimney enclosure.

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

36"

Fireplace

40"

12-8DM

Pipe Section

10 5/8"

12-8HT

 

 

18-8DM

Pipe Section

16 5/8"

18-8HT

 

 

24-8DM

Pipe Section

23 5/8"

24-8HT

 

 

36-8DM

Pipe Section

34 5/8"

36-8HT

 

 

48-8DM

Pipe Section

46 5/8"

48-8HT

 

 

RT-8DM

Round Termination

6 7/8"*

RTL-8DM

Round Termination

7 3/4"*

RTT-8DM

Round Termination

6 7/8" to

with Slip Section

23 1/8"*

RTTL-8DM

Round Termination

8 1/2" to

with Slip Section

21 1/2"*

ET-8DM

Square Chase-Top

12"*

ETO-8DM

Square Chase-Top

12"*

 

with Mesh

 

ETL-8DM

Square Chase-Top

7" to 15"*

 

with Slip Section

 

 

Square Chase-Top

12" to

ETLO-8DM

with Mesh & Slip

25 1/2"*

 

Section

 

*The lineal gain for the terminations is mea- sured to the flue gas outlet height.

12 3/8" Galvanized

Outer Pipe

8" Stainless

Hemmed

End

Inner Pipe

 

Figure 6 - Lineal Gain

Assembly and installation of double wall chimney system

Each double wall chimney section consists of a galvanized outer pipe, a stainless steel inner flue pipe and a wire spacer. The pipe sections must be assembled independently as the chimney is installed.

6

www.fmiproducts.com