Venting Installation
Optional Outside air Kit (Model ak4/ak4f)
The installation of an outside air kit should be performed during the rough framing of the fireplace due to the nature of it's location. Outside combustion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4). See Figure 22 on page 13 for instruction of operating air kit.
CAUTION: Combustion air inlet ducts shall not terminate in attic space.
The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination.
Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size)
Air Inlet
Location
Must Allow For Bushes or Snow
| Air Inlet | |
| Eyebrow | |
Vented Crawl Space | Vent Hood | |
Required for | ||
(Check Local Codes | ||
Wall Installation | ||
Before Installing in a | ||
| ||
Vented Crawl Space) |
| |
Figure 5 - Outside Air Kit |
Chimney Pipe
The FMI PRODUCTS, LLC chimney system
consists of 12", 18", 24", 36" and 48" snap- lock,
(lineal gain) and are given in the lineal gain
chart (see Figure 6). Lineal gain is the actual measurable length of a part after two or more parts are connected. For Canada, use chimney
parts designated "HT".
WARNING: The opening in collar around chimney at top of fireplace must not be obstruct- ed. Never use blown insulation to fill chimney enclosure.
LINEAL GAIN
PART NO. | DESCRIPTION | GAIN | |
36" | Fireplace | 40" | |
Pipe Section | 10 5/8" | ||
|
| ||
Pipe Section | 16 5/8" | ||
|
| ||
Pipe Section | 23 5/8" | ||
|
| ||
Pipe Section | 34 5/8" | ||
|
| ||
Pipe Section | 46 5/8" | ||
|
| ||
Round Termination | 6 7/8"* | ||
Round Termination | 7 3/4"* | ||
Round Termination | 6 7/8" to | ||
with Slip Section | 23 1/8"* | ||
Round Termination | 8 1/2" to | ||
with Slip Section | 21 1/2"* | ||
Square | 12"* | ||
Square | 12"* | ||
| with Mesh |
| |
Square | 7" to 15"* | ||
| with Slip Section |
| |
| Square | 12" to | |
with Mesh & Slip | |||
25 1/2"* | |||
| Section |
|
*The lineal gain for the terminations is mea- sured to the flue gas outlet height.
12 3/8" Galvanized
Outer Pipe
8" Stainless | Hemmed | |
End | ||
Inner Pipe | ||
|
Figure 6 - Lineal Gain
Assembly and installation of double wall chimney system
Each double wall chimney section consists of a galvanized outer pipe, a stainless steel inner flue pipe and a wire spacer. The pipe sections must be assembled independently as the chimney is installed.
6 | www.fmiproducts.com |