INSTALLATION
Continued
PRESSURE TESTING FIREPLACE GAS CONNECTIONS
1.Open equipment shutoff valve (see Figure 18, page 16).
2.Open main gas valve located on or near gas meter for natural gas or open pro- pane/LP supply tank valve.
3.Make sure control knob of fireplace is in the OFF position.
4.Check all joints from equipment shutoff valve to gas control valve (see Figures
19 or 20, page 16). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.
5.Correct all leaks at once.
6.Light fireplace (see Operation, page 20.)
Check all other internal joints for leaks.
3. Replace battery housing cover.
When batteries are installed, the "little house" icon with current room temperature will be displayed (see Figure 22). This icon will always show in the control window as long as the batteries have power.
Figure 22 - Remote Display
7.Turn off fireplace (see To Turn Off Gas to Appliance, page 21.
INSTALLING BATTERIES IN REMOTE CONTROL AND RECEIVER
Remote Receiver
The remote receiver uses 4 AA batteries (not included). To install or replace batteries:
1.Open lower louver to gain access to re- ceiver.
WARNING: Make sure your selector switch is in OFF position before installing or changing batteries in your
The
To install batteries:
1.Remove battery housing cover from back of
2.Install or replace batteries.
Battery Housing
Cover
|
|
|
|
| - | AAA | + |
|
|
|
|
| + | AAA | - |
| |||
|
|
|
|
| - | AAA | + |
2.Remove screws from cover place.
3.Remove battery housing cover.
4.Install or replace batteries.
5.Replace battery housing cover.
6.Replace cover plate.
Receiver
Battery Housing
Cover
Cover Plate
Screws
Figure 23 - Battery Install Remote
Control Receiver
Figure 21 - Battery Install
Remote Control
www.fmiproducts.com | 17 |