SPECIFICATIONS

Model VSGF36NRC

Rating (Variable): 33,000/21,500 Btu/Hr

Type Gas: Natural Gas

Ignition: Electronic

Pressure Manifold: 3.5" W.C.

Inlet Gas Pressure (in. of water): Maximum 10.5" W.C., Minimum* 5" W.C.

Shipping Weight: 120 lbs.

* For input adjustment

Model VSGF36PRC

Rating (Variable): 33,000/21,500 Btu/Hr

Type Gas: Propane/LP

Ignition: Electronic

Pressure Manifold: 7.9" W.C.

Inlet Gas Pressure (in. of water):

Maximum 13" W.C. Minimum* 11" W.C.

Shipping Weight: 120 lbs.

* For input adjustment

TECHNICAL SERVICE

You may have further questions about installa- tion, operation or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537. When calling, please have your model and serial numbers of your firebox ready.

You can also visit FMI PRODUCTS, LLC’s web site at www.fmiproducts.com.

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low for propane/LP unit

You may feel your gas pressure is too low. If so, contact your local gas supplier.

WIRING DIAGRAM

Note: For proper operation of remote control, wires from thermopile to control receiver must be connected exactly as shown.

Black Connectors

Receiver

 

White

To Thermopile

Red

Figure 47 - Remote Control Wiring Diagram

30

www.fmiproducts.com

121082-01K