Operation

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knobwillnotpushinorturnbyhand,don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information above.

2.Make sure equipment shutoff valve is fully open.

3.Turn off any electric power to the appli- ance if service is to be performed.

4.Turn control knob clockwise to the

OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B”

in the safety information, column 1. If you don’t smell gas, go to the next step.

6.Thermostat Models: Turn control knob

counterclockwise to the PILOT position. Press in control knob for five (5) seconds.

Manual Models: Press in and turn control

knob counterclockwise to the PILOT position. Keep control knob pressed in for five (5) seconds.

7.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. Note: You may be running this heater for the first time after hooking up to gas supply. If so, you may need to press in control knob for 30 seconds or more. This will allow air to bleed from the gas system. If needed, keep pressing ignitor button until pilot lights. If ignitor does not light pilot, refer to Troubleshooting, page 18 or contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 16.

8.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob.

• If control knob does not pop out when released, contact a qualified service per- son or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 7. Wait one (1) minute before lighting pilot

9.Turn control knob counterclockwise to desired heating level. The main burner should light. Manual control heaters should be used in locked positions.

Control

Knob

Figure 19 - Control Knob in the OFF Position for Manual Control Models

Control

Knob

Figure 20 - Control Knob in the OFF

Position for Thermostat Models

14

www.fmiproducts.com

125311-01A