NO = No third food probe fitted. YES = Third food probe fitted.
P93 Food 3 Offset
Allows the value of Food Probe 3 to be offset allowing for the product temperature to be accurately measured.
Range -15°C to +15°C.
P94 Address
The controller peripheral number. This is only necessary when controller are linked via a network to a computer
management and data recording system (such as with the Foster TAB or ARGO systems).
Range 00 to 255.
Alarm and Warnings
In general if an alarm occurs the appropriate alarm symbol will be displayed and the alarm will sound to attract attention.
The cabinet will attempt to continue running or to finish the cycle (if safe to do so).
The distinction between an alarm and a warning is that a warning may be a non-critical occurrence such as door open or
temporary power failure. An alarm would be for a system failure such as a probe fault or high-pressure fault, which would
require positive intervention.
High pressure developing in the refrigeration system as a result of, to high food temperature,
condenser fan failure, blocked condenser, air flow restriction etc. Automatically re – sets
when the normal working pressure is achieved.
Air Probe Fault
Evaporator Probe Fault
Food Probe Fault. If more than 1 probe are enabled the probe fault would be displayed
accordingly
Door 2 open. Will not allow any chill, defrost or UV Sanitisation programs to be run if the door
is open.
Ribbon cable between the power switching PCB and the display disconnected.
18