ELECTRICAL CONNECTION

Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.

Remove the grease filters (see paragraph Mainte- nance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.

Flue assembly

Upper exhaust flue

• Slightly widen the two sides of the upper flue and

hook them behind the brackets 7.2.1, making sure

2.1

that they are well seated.

 

• Secure the sides to the brackets using the 4 screws

2

12c (2,9 x 9,5) supplied.

 

• Make sure that the outlet of the extensions pieces is

2.2

aligned with the chimney outlets.

 

Lower exhaust flue

Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated.

Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 9,5) supplied.

7.2.1

12c

12c