Mountingthehoodbody

• Beforeattachingthehoodbody,tightenthetwos

crews Vrlo

catedonthehoodbodymountingpoints.

 

 

• Hookthehoodbodyontothescrews

12a.

 

• Fullytightensupportscrews 12a.

 

 

• Adjustscrews Vrtolevelthehoodbody.

 

Connections

DUCTEDVERSIONAIREXHAUSTSYSTEM

 

When installing the ducted version, connect the hoo

d to the

chimneyusingeitheraflexibleorrigidpipeø150

 

or120mm,

thechoiceofwhichislefttotheinstaller.

 

 

• To installaø 120 mmairexhaustconnection,ins

 

ertthere

ducerflange 9onthehoodbodyoutlet.

 

 

• Fixthepipeinpositionusingsufficientpipecl

amps(notsup

plied).

 

 

• Removeanyactivatedcharcoalfilters.

 

 

RECIRCULATIONVERSIONAIROUTLET

• Putconnection 15intotheconnectionsupport

7.3.

Inserttheconnectionextensionpieceslaterally 14.1inconnec tion 15.

Makesurethattheoutletoftheextensionpieces 14.1ishori

zontallyandverticallyalignedwiththechimneyou

tlets.

• Connecttheairoutletconnection

15tothehoodbodyoutlet

usingeitheraflexibleorrigidpipe ø150mm,t

 

hechoiceof

whichislefttotheinstaller.

 

 

 

•Ensurethattheactivatedcharcoalfiltershave

beeninserted.

Vr

12a

ø 150

ø 120

9

14.1

15

ø150

EN

 

1

 

17

Page 17