Franke Consumer Products FSL 905 BK/XS ECS manual Maintenance, Grease filters, Light Replacement

Models: FSL 905 WH/XS ECS FSL 905 BK/XS ECS

1 60
Download 60 pages 3.48 Kb
Page 10
Image 10

MAINTENANCE

Grease filters

CLEANING METAL SELF- SUPPORTING GREASE FILTERS

• The filters must be cleaned every 2 months of opera- tion, or more frequently for particularly heavy usage, and can be washed in a dishwasher.

• Remove the filters one at a time by pushing them to- wards the back of the group and pulling down at the same time.

• Wash the filters, taking care not to bend them. Allow them to dry before refitting.

When refitting the filters, make sure that the handle is visible on the outside.

Activated charcoal filter (Recirculation version)

REPLACING THE ACTIVATED CHARCOAL FILTER

The filter is not washable and cannot be regenerated, and must be replaced approximately every 4 months

of operation, or more frequently for particularly heavy usage.

• Remove the metal grease filters.

• Remove the saturated activated carbon filter by re- leasing the fixing hooks.

Fit the new filter by hooking it into its seating.

Refit the metal grease filters.

Lighting

LIGHT REPLACEMENT

20 W halogen light.

• Extract the lamp from the lamp holder by pulling gently.

• Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.

EN

 

1

 

10

Page 10
Image 10
Franke Consumer Products FSL 905 BK/XS ECS Maintenance, Grease filters, Activated charcoal filter Recirculation version