Freecom Technologies RCS-M2000T Window Panel Kit Optional Accessory, Accessory Installation

Models: RCS-M2000U RCS-M2000T

1 16
Download 16 pages 51.96 Kb
Page 11
Image 11
Window Panel Kit (Optional Accessory)

ACCESSORY INSTALLATION

Window Panel Kit (Optional Accessory)

The Window Panel Kit is an accessory which, when used with the Exhaust Duct Kit, will increase cooling efficiency by directing warm air exhaust out a window and preventing outside air from getting into the room.

1.Extend panels to fit in window opening. For vertical windows, be sure cut-out is to the bottom.

2.To secure panels in place, install set screws into two smaller holes on outer panel.

3.Locate two long, rubber weather strips. Hold flat side of weather strips along outside of outer panel (with cutout). Slide weather strips into rails on each side of outer panel.

4.Locate two short, rubber weather strips. Hold flat side of weather strips along outside of inner panel. Slide weather strips into rails on each side of inner panel.

5.Cut the two short, rubber weather strips to align with end of inner panel. Use care when cutting weather strips.

6.Place Window Panel Kit into window opening. Close window tightly against Window Panel Kit.

7.Install the outlet nozzle of the Exhaust Duct Kit into the cut-out in the outer panel. The outlet nozzle fits tightly into the cut-out.

11

Page 11
Image 11
Freecom Technologies RCS-M2000T, RCS-M2000U operation manual Window Panel Kit Optional Accessory, Accessory Installation