Friedrich BR1224W3A, Breeze installation instructions Place the mounting pad

Models: Breeze BR1224W3A

1 8
Download 8 pages 24.63 Kb
Page 6
Image 6
STEP 6 - Place the mounting pad.

STEP 6 - Place the mounting pad.

Position the mounting pad so that the mounting holes are away from the house. Set the outdoor module on the mounting pad so that the module feet align with the mounting holes. Screw the outdoor module to the mounting pad with the 4 condenser pad installation washers and screws provided (Items #8 and #9 in the Accessories List).

STEP 6

STEP 7 – Connect the quick connector from the indoor line set outdoor module.

1.Open lock handle on line- set connector by pulling back and rotating toward indoor unit.

2.Grasp outer lock collar on line-set connector and pull back until it stops.

3.While holding outer lock collar rearward, push line- set connector body over base connector on outdoor unit half way and release outer lock collar.

4.Continue to push line-set connector onto base con- nector until outer lock col- lar engages base connector. The outer lock collar will snap into position with base connector and a click will be heard.

5. Grasp lock handle and

 

6. Install security screw

 

rotate to its closed posi-

 

(Item 13 in the Accessories

tion.

 

List) to prevent tampering

 

 

 

 

 

 

with line-set connector

 

 

 

 

 

 

mechanism.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If you have excess connecting line, roll the line into a coil approximately 2 feet wide, secure with the provided wire ties and store between the outdoor module and the wall. DO NOT cut or kink the connecting line!

STEP 8 – Connect the electrical connector from the connecting line to outdoor module

1.Connect the black colored electrical connector from the connecting line into the mating connector on the outdoor module. The connectors will snap into place with a click. (The plug can be removed by pushing in the side tabs on the plug and pulling

the plug body down and out of the receptacle.)

Item #6

 

2. Install the electrical cord retention bracket (Item #6 in the Accessories List) using Item #10 two #8 x 3/4” screws (Item #10 in the Accessories List). The opening in the electrical

cord retention bracket should fit over the cord. Do not pinch the cord in the bracket.

3.Install the plastic cover (Item #2 in the Accessories List) as shown. There is one screw located on the lower right flange of the cover and one screw under the elec- trical connector access cover. Once secure, use enclosed screw (Item #10 in the Accessories List) to close the access door.

4.Install the quick connect cover as shown in figure 4. Once in place secure using

enclosed #8 x 3/4” screw located on the top flange of the quick connect cover.

Item #10

All Covers must be in place to operate unit.

SHOCK HAZARD exists without electrical access cover.

Cover cannot be installed without completing steps 8.1 through 8.4 properly.

1.

2.

3.

Page 6